Characterization of a diode dosimeter for UHDR FLASH radiotherapy.

Mahbubur Rahman, Jakub Kozelka, Jeff Hildreth, Andreas Schönfeld, Austin M Sloop, M Ramish Ashraf, Petr Bruza, David J Gladstone, Brian W Pogue, William E Simon and 1 more

Abstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Timescale of FLASH Sparing Effect Determined by Varying Temporal Split of Dose Delivery in Mice.International journal of radiation oncology, biology, physics · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Mahbubur RahmanThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
Jakub KozelkaSun Nuclear Inc., Melbourne, Florida, USA.
Jeff HildrethSun Nuclear Inc., Melbourne, Florida, USA.
Andreas SchönfeldSun Nuclear Inc., Melbourne, Florida, USA.
Austin M SloopThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
M Ramish AshrafThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
Petr BruzaThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
David J GladstoneThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
Brian W PogueThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
William E SimonSun Nuclear Inc., Melbourne, Florida, USA.
Rongxiao ZhangThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.

Funding

Translational Engineering in Cancer (TEC)P30CA023108 · NCI · DARTMOUTH COLLEGE · PI Steven D Leach · 1985 to 2026
$91.3M
Optimization of MeV FLASH radiotherapy for normal tissue preservationU01CA260446 · NCI · DARTMOUTH COLLEGE · PI David J. Gladstone, Jack Hoopes · 2022 to 2026
$3.1M
Cerenkov excited luminescence sheet imaging (CELSI)R01EB024498 · NIBIB · DARTMOUTH COLLEGE · PI POGUE, BRIAN WILLIAM · 2017 to 2020
$2.2M
NCI NIH HHS P30 CA023108NCI NIH HHS U01 CA260446NIBIB NIH HHS R01 EB024498
6 · The paper itself

Abstract

backgroundUltra-high dose rate (UHDR) FLASH beams typically deliver dose at rates of  >40 Gy/sec. Characterization of these beams with respect to dose, mean dose rate, and dose per pulse requires dosimeters which exhibit high temporal resolution and fast readout capabilities. PURPOSE: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry.

methodsDose linearity, mean dose rate, and dose per pulse dependencies of the EDGE Detector were quantified and compared with dosimeters including a W1 scintillator detector, radiochromic film, and ionization chamber that were irradiated with a 10 MeV UHDR beam. The dose, dose rate, and dose per pulse were controlled via an in-house developed scintillation-based feedback mechanism, repetition rate of the linear accelerator, and source-to-surface distance, respectively. Depth-dose profiles and temporal profiles at individual pulse resolution were compared to the film and scintillation measurements, respectively. The radiation-induced change in response sensitivity was quantified via irradiation of ∼5kGy.

resultsThe EDGE Detector agreed with film measurements in the measured range with varying dose (up to 70 Gy), dose rate (nearly 200 Gy/s), and dose per pulse (up to 0.63 Gy/pulse) on average to within 2%, 5%, and 1%, respectively. The detector also agreed with W1 scintillation detector on average to within 2% for dose per pulse (up to 0.78 Gy/pulse). The EDGE Detector signal was proportional to ion chamber (IC) measured dose, and mean dose rate in the bremsstrahlung tail to within 0.4% and 0.2% respectively. The EDGE Detector measured percent depth dose (PDD) agreed with film to within 3% and per pulse output agreed with W1 scintillator to within -6% to +5%. The radiation-induced response decrease was 0.4% per kGy.

conclusionsThe EDGE Detector demonstrated dose linearity, mean dose rate independence, and dose per pulse independence for UHDR electron beams. It can quantify the beam spatially, and temporally at sub millisecond resolution. It's robustness and individual pulse detectability of treatment deliveries can potentially lead to its implementation for in vivo FLASH dosimetry, and dose monitoring.

Indexed as

In Vivo DosimetryRadiation DosimetersParticle AcceleratorsRadiometrydiodeEDGE detectorfilmFLASHionization chamberultra-high dose rate

Identifiers

PMID37249058
PMCPMC11748214

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.