Development of a new coordinate calibration phantom for a light-section-based optical surface monitoring system.

Tatsunori Saito, Naoki Hayashi, Hiroshi Amma, Kazuki Onishi, Yuta Muraki, Masashi Nozue

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Tatsunori SaitoDepartment of Radiology, Seirei Hamamatsu General Hospital, 2-12-12, Sumiyoshi, Naka-Ward, Hamamatsu, Shizuoka, 430-8558, Japan.
Naoki HayashiSchool of Medical Sciences, Fujita Health University, 1-98, Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan. hayashi@fujita-hu.ac.jp.ORCID http://orcid.org/0000-0002-1720-3651
Hiroshi AmmaDepartment of Radiology, Seirei Hamamatsu General Hospital, 2-12-12, Sumiyoshi, Naka-Ward, Hamamatsu, Shizuoka, 430-8558, Japan.
Kazuki OnishiDepartment of Radiology, Seirei Hamamatsu General Hospital, 2-12-12, Sumiyoshi, Naka-Ward, Hamamatsu, Shizuoka, 430-8558, Japan.
Yuta MurakiDepartment of Radiology, Seirei Hamamatsu General Hospital, 2-12-12, Sumiyoshi, Naka-Ward, Hamamatsu, Shizuoka, 430-8558, Japan.
Masashi NozueDepartment of Radiation Oncology, Seirei Hamamatsu General Hospital, 2-12-12, Sumiyoshi, Naka-Ward, Hamamatsu, Shizuoka, 430-8558, Japan.
Seirei Hamamatsu General Hospital · JPFujita Health University Hospital · JP

Funding

Japan Society for the Promotion of Science London 22K12852
6 · The paper itself

Abstract

A calibration phantom made of Derlin requires manual translational and rotational adjustments when calibrating a light-section-based optical surface monitoring system (VOXELAN) with a phantom material that insufficiently reflects the red-slit laser of the system. This study aimed to develop a new calibration phantom using different materials and to propose a procedure that minimizes setup errors. The new phantom, primarily made of PET100, which exhibits good reflectivity without scattering or attenuating the red-slit laser at the phantom surface, was shaped in a manner similar to that of previous designs. The detection accuracy and stability were evaluated using six different regions of interest (ROIs) and compared with previous phantom designs. The coordinate coincidence between the machine and VOXELAN was compared for both phantom designs. The detection accuracy and stability of the new phantom in the reference ROI setting were found to be better than those of previous phantoms. In the lateral, longitudinal, and vertical directions, the coordinate coincidences in translational directions for the previous phantom were obtained at 1.07 ± 0.66, 1.46 ± 0.47, and 0.26 ± 0.83 mm, whereas those for the new phantom were obtained at 0.28 ± 0.21, 0.18 ± 0.30, and - 0.30 ± 0.29 mm, respectively. The rotational errors of the two phantoms were identical. The new phantom exhibited improved detection stability because of its good reflectivity. Additionally, the new placement procedure was linked to the six-degrees-of-freedom couch. A combination of the new phantom and its new placement procedure is suitable for coordinate calibration of VOXELAN.

Indexed as

CalibrationPhantoms, ImagingCalibrationLight-section methodQuality assuranceReflectivitySurface-guided radiation therapy

Identifiers

PMID37248443
OpenAlexW4378746257

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.