Evidence map›Paper›PMID 37247817›Full record

Trial reportBrazilian journal of anesthesiology (Elsevier)

Accuracy of closed-loop and open-loop propofol delivery systems by bispectral index monitoring in breast surgery patients: a prospective randomized trial.

Tian Xie, Yong Wang, Yuhua Liu, Junjie Li, Weijing Li, Hongmeng Xu

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Brazilian journal of anesthesiology (Elsevier). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tian XieForth Hospital of Hebei Medical University, Department of Anesthesiology, Hebei, China.
Yong WangForth Hospital of Hebei Medical University, Department of Anesthesiology, Hebei, China.
Yuhua LiuForth Hospital of Hebei Medical University, Department of Anesthesiology, Hebei, China.
Junjie LiForth Hospital of Hebei Medical University, Department of Anesthesiology, Hebei, China.
Weijing LiForth Hospital of Hebei Medical University, Department of Anesthesiology, Hebei, China.
Hongmeng XuForth Hospital of Hebei Medical University, Department of Anesthesiology, Hebei, China. Electronic address: xuhongmeng66@aliyun.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis randomized and controlled prospective study tested the hypothesis that closed-loop Target-Controlled Infusion (TCI) of propofol would be associated with better system performance when compared with open-loop controlled delivery of propofol.

methodsPatients scheduled for elective breast surgery were randomly assigned to two groups: a closed-loop group, in which propofol infusion was performed by a closed-loop TCI system that used the Bispectral Index (BIS) as a feedback parameter to titrate the rate of propofol infusion, and an open-loop group, in which propofol infusion was performed manually and guided by the bispectral index.

resultsA total of 156 patients were recruited for this study (closed-loop group n = 79; open-loop group n = 77). The Global Score (GS) of the closed-loop group was lower than that of the open-loop group (34.3 and 42.2) (p = 0.044). The proportions of time with a BIS value between 40 and 60 were almost identical in the closed-loop group and the open-loop group (68.7 ± 10.6% and 66.7 ± 13.3%) (p = 0.318). The individuals in the closed-loop group consumed more propofol compared with those in the open-loop group (7.20 ± 1.65 mg.kg

conclusionThe closed-loop protocol was associated with lower BIS variability and lower out-of-range BIS values, at the cost of a greater consumption of propofol when compared to the open loop group. REGISTER NUMBER: ChiCTR-INR-17010399.

Indexed as

Breast NeoplasmsPropofolAnesthesia, IntravenousAnesthetics, IntravenousElectroencephalographyFemaleHumansProspective StudiesAnesthetics, IntravenousPropofolAnesthesiaClosed-loopDrug delivery systemInfusion pumpIntravenousPropofol

Identifiers

PMID37247817
PMCPMC10963934

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.