ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2023
Osseointegration reduces aseptic loosening of primary distal femoral implants in pediatric and adolescent osteosarcoma patients: a retrospective clinical and radiographic study.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimThe challenge of distal femoral replacement (DFR) longevity remains a priority for orthopaedic oncologists as the overall survival and activity level of young patients with osteosarcoma continues to improve. This study hypothesized that increased extracortical osseointegration at the bone-implant shoulder (i.e., where the metal implant shaft abuts the femur) will improve stress transfer adjacent to the implant, as evidenced by reduced cortical bone loss, radiolucent line progression and implant failure in young patients (< 20 years) following DFR surgery.
methodsTwenty-nine patients of mean age 13.09 ± 0.56 years received a primary DFR. The clinical outcome of 11 CPS®, 10 GMRS®, 5 Stanmore® and 3 Repiphysis® implants was evaluated over a mean follow-up period of 4.25 ± 0.55 years. The osseous response to a bone-implant shoulder composed of either a hydroxyapatite-coated grooved ingrowth collar (Stanmore®), a porous metal coating (GMRS®) or a polished metal surface (Repiphysis®) was quantified radiographically.
resultsAll (100.0%) of the Stanmore® implants, 90.0% of GMRS®, 81.8% of CPS® and 33.3% of the Repiphysis® implants survived. Significantly increased extracortical bone and osseointegration were measured adjacent to the Stanmore® bone-implant shoulder when compared with the GMRS® and Repiphysis® implants (p < 0.0001 in both cases). Significantly decreased cortical loss was identified in the Stanmore® group (p = 0.005, GMRS® and p < 0.0001, Repiphysis®) and at 3 years, the progression of radiolucent lines adjacent to the intramedullarly stem was reduced when compared with the GMRS® and Repiphysis® implants (p = 0.012 and 0.026, respectively).
conclusionsImplants designed to augment osseointegration at the bone-implant shoulder may be critical in reducing short- (≤ 2 years) to mid- (≤ 5 years) term aseptic loosening in this vulnerable DFR patient group. Further longer-term studies are required to confirm these preliminary findings.