Evidence map›Paper›PMID 37246333›Full record

ArticleInternational journal for numerical methods in biomedical engineering2023

Mesh-free high-resolution simulation of cerebrocortical oxygen supply with fast Fourier preconditioning.

Thomas Ventimiglia, Andreas A Linninger

Open access · hybridAbstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Vascular synthesis based on hemodynamic efficiency principle recapitulates measured cerebral circulation properties in the human brain.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2024
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Thomas VentimigliaDepartment of Mathematical Sciences, Northern Illinois University, Dekalb, Illinois, USA.
Andreas A LinningerDepartment of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0002-2694-630X
Northern Illinois University · USUniversity of Illinois Chicago · US

Funding

Project 4U19NS123717 · NINDS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI LINNINGER, ANDREAS A · 2021 to 2025
$13.4M
Image-based cerebrovascular network snythesis(iCNS) to model Alzheimer's DiseaseR01AG079894 · NIA · UNIVERSITY OF ILLINOIS AT CHICAGO · PI ANDREAS A LINNINGER · 2023 to 2026
$2.9M
Models for aging and Alzheimer with image-based cerebrovascular network synthesis (iCNS)R56AG066634 · NIA · UNIVERSITY OF ILLINOIS AT CHICAGO · PI LINNINGER, ANDREAS A · 2020 to 2020
$744k
NIA NIH HHS 1R01AG079894-01NIA NIH HHS R01 AG079894NIA NIH HHS R56 AG066634NINDS NIH HHS 1U19NS123717-01NINDS NIH HHS U19 NS123717
6 · The paper itself

Abstract

Oxygen transfer from blood vessels to cortical brain tissue is representative of a class of problems with mixed-domain character. Large-scale efficient computation of tissue oxygen concentration is dependent on the manner in which the tubular network of blood vessels is coupled to the tissue mesh. Models which explicitly resolve the interface between the tissue and vasculature with a contiguous mesh are prohibitively expensive for very dense cerebral microvasculature. We propose a mixed-domain mesh-free technique whereby a vascular anatomical network (VAN) represented as a thin directed graph serves for convection of blood oxygen, and the surrounding extravascular tissue is represented as a Cartesian grid of 3D voxels throughout which oxygen is transported by diffusion. We split the network and tissue meshes by the Schur complement method of domain decomposition to obtain a reduced set of system equations for the tissue oxygen concentration at steady state. The use of a Cartesian grid allows the corresponding matrix equation to be solved approximately with a fast Fourier transform-based Poisson solver, which serves as an effective preconditioner for Krylov subspace iteration. The performance of this method enables the steady-state simulation of cortical oxygen perfusion for anatomically accurate vascular networks down to single micron resolution without the need for supercomputers.

Indexed as

OxygenComputer SimulationDiffusionFourier AnalysisOxygencerebral vasculaturehigh resolutionmathematical modelingmicrovasculaturemixed-domainoxygen perfusionpreconditioning

Identifiers

PMID37246333
PMCPMC10524481
OpenAlexW4378627750

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.