ArticlePhysical and engineering sciences in medicine2023
Comparison of organ dose from chest radiography with varying beam quality and constant exposure index.
Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- A novel method for measuring the backscatter factor on a curved surface for diagnostic X-rays using a flexible scintillator sheet.Physical and engineering sciences in medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The optimum X-ray tube voltage for chest radiographic examinations remains unclear; hence, the tube voltage varies between medical facilities. An exposure index (EI) was proposed to standardize the parameters for radiographic examinations. However, even if identical EI values are used to examine the same person, organ doses may vary due to differences in tube voltages. In this study, the variation in organ doses between different beam qualities under identical EI values for chest radiographic examinations was investigated using Monte Carlo simulations. A focused anti-scatter grid as well as standard and larger physique-type medical internal radiation dose (MIRD) phantoms were studied under tube voltages of 90, 100, 110, and 120 kVp. The organ doses in the MIRD phantom increased as the X-ray tube voltage decreased, even with identical EI values. The absorbed doses in the lungs of standard and large-sized MIRD phantoms at 90 kVp were 23% and 35% higher than those at 120 kVp, respectively. The doses to organs other than the lung at 90 kVp were also higher than those at 120 kVp. From the perspective of reducing radiation doses, a tube voltage of 120 kVp is considered better for chest examinations compared with a tube voltage of 90 kVp under identical EI values.