Evidence map›Paper›PMID 37245193›Full record

ArticlePhysical and engineering sciences in medicine2023

Comparison of organ dose from chest radiography with varying beam quality and constant exposure index.

Kohei Nakanishi

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Kohei NakanishiDepartment of Integrated Health Science, Nagoya University Graduate School of Medicine, Nagoya, Japan. k.nakanishi@met.nagoya-u.ac.jp.ORCID http://orcid.org/0000-0003-3135-1017
Nagoya University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The optimum X-ray tube voltage for chest radiographic examinations remains unclear; hence, the tube voltage varies between medical facilities. An exposure index (EI) was proposed to standardize the parameters for radiographic examinations. However, even if identical EI values are used to examine the same person, organ doses may vary due to differences in tube voltages. In this study, the variation in organ doses between different beam qualities under identical EI values for chest radiographic examinations was investigated using Monte Carlo simulations. A focused anti-scatter grid as well as standard and larger physique-type medical internal radiation dose (MIRD) phantoms were studied under tube voltages of 90, 100, 110, and 120 kVp. The organ doses in the MIRD phantom increased as the X-ray tube voltage decreased, even with identical EI values. The absorbed doses in the lungs of standard and large-sized MIRD phantoms at 90 kVp were 23% and 35% higher than those at 120 kVp, respectively. The doses to organs other than the lung at 90 kVp were also higher than those at 120 kVp. From the perspective of reducing radiation doses, a tube voltage of 120 kVp is considered better for chest examinations compared with a tube voltage of 90 kVp under identical EI values.

Indexed as

BreastFluoroscopyHumansMonte Carlo MethodPhantoms, ImagingRadiation DosageChest radiographic examinationExposure indexMonte CarloOrgan dosesTube voltageX-ray

Identifiers

PMID37245193
OpenAlexW4378576539

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked