ArticleInternational journal of computer assisted radiology and surgery2023
Recurrent neural networks for generalization towards the vessel geometry in autonomous endovascular guidewire navigation in the aortic arch.
Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 15 citations in OpenAlex.
- Vascular geometry characterization for AI-based endovascular navigation.International journal of computer assisted radiology and surgery · 2026Article
- Advancements and challenges in autonomous endovascular interventional robotics: A comprehensive review.iScience · 2025Review
- Article
- Reinforcement learning for safe autonomous two-device navigation of cerebral vessels in mechanical thrombectomy.International journal of computer assisted radiology and surgery · 2025Article
- Benchmarking reinforcement learning algorithms for autonomous mechanical thrombectomy.International journal of computer assisted radiology and surgery · 2025Article
- Advanced Robotics for the Next-Generation of Cardiac Interventions.Micromachines · 2025Review
- Autonomous navigation of catheters and guidewires in mechanical thrombectomy using inverse reinforcement learning.International journal of computer assisted radiology and surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeEndovascular intervention is the state-of-the-art treatment for common cardiovascular diseases, such as heart attack and stroke. Automation of the procedure may improve the working conditions of physicians and provide high-quality care to patients in remote areas, posing a major impact on overall treatment quality. However, this requires the adaption to individual patient anatomies, which currently poses an unsolved challenge.
methodsThis work investigates an endovascular guidewire controller architecture based on recurrent neural networks. The controller is evaluated in-silico on its ability to adapt to new vessel geometries when navigating through the aortic arch. The controller's generalization capabilities are examined by reducing the number of variations seen during training. For this purpose, an endovascular simulation environment is introduced, which allows guidewire navigation in a parametrizable aortic arch.
resultsThe recurrent controller achieves a higher navigation success rate of 75.0% after 29,200 interventions compared to 71.6% after 156,800 interventions for a feedforward controller. Furthermore, the recurrent controller generalizes to previously unseen aortic arches and is robust towards size changes of the aortic arch. Being trained on 2048 aortic arch geometries gives the same results as being trained with full variation when evaluated on 1000 different geometries. For interpolation a gap of 30% of the scaling range and for extrapolation additional 10% of the scaling range can be navigated successfully.
conclusionAdaption to new vessel geometries is essential in the navigation of endovascular instruments. Therefore, the intrinsic generalization to new vessel geometries poses an essential step towards autonomous endovascular robotics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.