Evidence map›Paper›PMID 37245012›Full record

Trial reportBMC pulmonary medicine2023

High diagnostic yield of electromagnetic navigation bronchoscopy performed under cone beam CT guidance: results of a randomized Belgian monocentric study.

Benjamin Bondue, Olivier Taton, Fadi Tannouri, Nikita Van de Velde, Myriam Remmelink, Dimitri Leduc

Registry-linked trialOpen access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in BMC pulmonary medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05257382 (A Randomized Controlled Study Evaluating the Added Value of an Hybrid Room Equipped With a Cone Beam CT), which is not on this map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
6.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05257382 nacompletednot on this map

A Randomized Controlled Study Evaluating the Added Value of an Hybrid Room Equipped With a Cone Beam CT (CBCT) to Electromagnetic Navigation Bronchoscopy (ENB) for the Diagnosis of Pulmonary Nodule.

TypeinterventionalSponsorErasme University HospitalRan2020 to 2022Enrolled49ConditionsLung Cancer, Pulmonary DiseaseArmsENB followed by trans-bronchial biopsy and trans-bronchial cryobiopsy
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Benjamin BondueDepartment of Pneumology, Hôpital Erasme, Université Libre de Bruxelles, 808 Route de Lennik, 1070, Brussels, Belgium. benjamin.bondue@erasme.ulb.ac.be.
Olivier TatonDepartment of Pneumology, Hôpital Erasme, Université Libre de Bruxelles, 808 Route de Lennik, 1070, Brussels, Belgium.
Fadi TannouriDepartment of Radiology, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium.
Nikita Van de VeldeDepartment of Pneumology, Hôpital Erasme, Université Libre de Bruxelles, 808 Route de Lennik, 1070, Brussels, Belgium.
Myriam RemmelinkDepartment of Pathology, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium.
Dimitri LeducDepartment of Pneumology, Hôpital Erasme, Université Libre de Bruxelles, 808 Route de Lennik, 1070, Brussels, Belgium.
Erasmus Hospital · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWith the increasing use of low dose CT scans, numerous pulmonary nodules are detected. As majority of them are benign, development of efficient non-surgical diagnostic intervention is mandatory. Electromagnetic navigation bronchoscopy (ENB) has been developed to reach difficult to access lesions. The aim of the present study was to compare the diagnostic yield of ENB procedures performed in a classical endoscopy suite or in a hybrid room equipped by a cone beam CT (CBCT).

methodsA monocentric randomized study was performed in the Erasme Hospital between January 2020 and December 2021. Lung nodules of maximum 30 mm of diameter were eligible. In both arms (endoscopy or CBCT suites), ENB, fluoroscopic guidance and a radial endobronchial ultrasound were used to reach the lesion. Then six trans-bronchial biopsies (TBB) and one trans-bronchial lung cryobiopsy (TBLC) were performed. Primary outcomes were the diagnostic yield and diagnostic accuracy of the procedure.

resultsForty-nine patients were randomized (24 in the endoscopy and 25 in the CBCT arms). The lesion size was 15,9 ± 4,6 mm and 16,6 ± 6,0 mm respectively (mean ± SD, p = NS). The diagnostic yield of ENB performed under CBCT guidance was 80% compared to 42% when performed in the endoscopy suite under standard fluoroscopic guidance (p < 0,05). Similarly, the diagnostic accuracy in the CBCT group was 87% compared to 54% for the endoscopy group (p < 0,05). Duration of the procedure in the CBCT and endoscopy arms was 80 ± 23 and 61 ± 13 min respectively (mean ± SD, p < 0,01). Performing TBLC in addition to TBB increased the diagnostic yield by 14% (17 and 12,5% in CBCT and endoscopy suites respectively, p = NS).

conclusionThis study highlighted the additional value to perform ENB procedure under CBCT guidance for small size (less than 2 cm of diameter) pulmonary nodules.

trial registrationClinical trial registration number: NCT05257382.

Indexed as

Lung NeoplasmsMultiple Pulmonary NodulesBelgiumBronchoscopyCone-Beam Computed TomographyElectromagnetic PhenomenaHumansBronchoscopyCone beam computed tomographyElectromagnetic navigation bronchoscopyLung cancerPulmonary noduleTrans-bronchial lung cryobiopsy

Identifiers

PMID37245012
PMCPMC10224575
OpenAlexW4378574512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.