Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed.
- Validation of ring-type cuffless blood pressure (BP) monitoring device for detecting awake-asleep BP variations compared to ambulatory BP monitoring device.Hypertension research : official journal of the Japanese Society of Hypertension · 2026Article
- Arterial blood pressure waveform reconstruction estimation from PPG using TCN-BiLSTM.American heart journal plus : cardiology research and practice · 2026Article
- Towards trustworthy AI-driven cuffless blood pressure monitoring.NPJ digital medicine · 2026Article
- Design considerations for hypertension chronotherapy trials: insights from experience and modelling.BMC medicine · 2026Review
- Evaluating cross-dataset transfer learning for photoplethysmography-based blood pressure estimation.Scientific reports · 2026Article
- Beyond the Cuff: State-of-the-Art on Cuffless Blood Pressure Monitoring.Sensors (Basel, Switzerland) · 2026Review
- Review
- Optical methods for cuffless blood pressure measurements.Biophotonics discovery · 2026Review
- Reliable wrist PPG monitoring by mitigating poor skin sensor contact.Scientific reports · 2025Article
- Digital hypertension - what we need for the high-quality management of hypertension in the new era.Hypertension research : official journal of the Japanese Society of Hypertension · 2025Review
- Harnessing operating room signals to estimate mean arterial pressure with AnesthNet.Scientific reports · 2025Article
- Cuffless Blood Pressure Measurement: Where Do We Actually Stand?Hypertension (Dallas, Tex. : 1979) · 2025Review
- Multi-point sensing organic light-emitting diode display based mobile cardiovascular monitor.Nature communications · 2025Article
- Feasibility of smart ring-based remote monitoring in hospitalized patients: evaluation of signal transmission latency and data acquisition continuity.Frontiers in bioengineering and biotechnology · 2025Article
- BP-Net: Monitoring "Changes" in Blood Pressure Using PPG With Self-Contrastive Masking.IEEE journal of biomedical and health informatics · 2024Article
- Assessment of blood pressure variability: characteristics and comparison of blood pressure measurement methods.Hypertension research : official journal of the Japanese Society of Hypertension · 2024Review
- Artificial intelligence-enhanced patient evaluation: bridging art and science.European heart journal · 2024Review
- Transforming Healthcare: The AI Revolution in the Comprehensive Care of Hypertension.Clinics and practice · 2024Review
- Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice: JACC State-of-the-Art Review.Journal of the American College of Cardiology · 2024Review
- History and evolution of blood pressure measurement.Clinical hypertension · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text], [Formula: see text], and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel 'standard deviation of subject-calibration centring (SDS)' metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials