Evidence map›Paper›PMID 37244974›Full record

ArticleScientific reports2023

Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations.

Jingon Joung, Chul-Woo Jung, Hyung-Chul Lee, Moon-Jung Chae, Hae-Sung Kim, Jonghun Park, Won-Yong Shin, Changhyun Kim, Minhyung Lee, Changwoo Choi

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Arterial blood pressure waveform reconstruction estimation from PPG using TCN-BiLSTM.American heart journal plus : cardiology research and practice · 2026
    Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Article
  10. Digital hypertension - what we need for the high-quality management of hypertension in the new era.Hypertension research : official journal of the Japanese Society of Hypertension · 2025
    Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Assessment of blood pressure variability: characteristics and comparison of blood pressure measurement methods.Hypertension research : official journal of the Japanese Society of Hypertension · 2024
    Review
  17. Review
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jingon JoungDepartment of Electrical and Electronics Engineering, Chung-Ang University, Seoul, 06974, South Korea. jgjoung@cau.ac.kr.
Chul-Woo JungDepartment of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, 03080, South Korea.
Hyung-Chul LeeDepartment of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, 03080, South Korea.
Moon-Jung ChaeDepartment of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea.
Hae-Sung KimDepartment of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea.
Jonghun ParkDepartment of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea.
Won-Yong ShinSchool of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, 03722, South Korea.
Changhyun KimSky Labs Inc., Seongnam, 13486, South Korea.
Minhyung LeeSky Labs Inc., Seongnam, 13486, South Korea.
Changwoo ChoiSky Labs Inc., Seongnam, 13486, South Korea. ian.choi@skylabs.io.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text], [Formula: see text], and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel 'standard deviation of subject-calibration centring (SDS)' metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services.

Indexed as

HypertensionPhotoplethysmographyArtificial IntelligenceBlood PressureBlood Pressure DeterminationHumansPulse Wave Analysis

Identifiers

PMID37244974
PMCPMC10224938

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.