Evidence map›Paper›PMID 37241953›Full record

ArticleMolecules (Basel, Switzerland)2023

An Automated Continuous Synthesis and Isolation for the Scalable Production of Aryl Sulfonyl Chlorides.

Matthew Glace, Cameron Armstrong, Nathan Puryear, Colin Bailey, Roudabeh Sadat Moazeni-Pourasil, Drew Scott, Sherif Abdelwahed, Thomas D Roper

Abstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Matthew GlaceDepartment of Chemical and Life Sciences Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.ORCID 0000-0002-6342-4850
Cameron ArmstrongDepartment of Chemical and Life Sciences Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.ORCID 0000-0001-6342-0860
Nathan PuryearDepartment of Electrical and Computer Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.ORCID 0000-0002-2463-9066
Colin BaileyDepartment of Chemical and Life Sciences Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.ORCID 0009-0008-9935-9094
Roudabeh Sadat Moazeni-PourasilDepartment of Chemical and Life Sciences Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.
Drew ScottDepartment of Chemical and Life Sciences Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.
Sherif AbdelwahedDepartment of Electrical and Computer Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.
Thomas D RoperDepartment of Chemical and Life Sciences Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA.ORCID 0000-0002-8923-5505

Funding

Biomedical Advanced Research and Development Authority 75A50120D00092
6 · The paper itself

Abstract

In this work, a continuous system to produce multi-hundred-gram quantities of aryl sulfonyl chlorides is described. The scheme employs multiple continuous stirred-tank reactors (CSTRs) and a continuous filtration system and incorporates an automated process control scheme. The experimental process outlined is intended to safely produce the desired sulfonyl chloride at laboratory scale. Suitable reaction conditions were first determined using a batch-chemistry design of experiments (DOE) and several isolation methods. The hazards and incompatibilities of the heated chlorosulfonic acid reaction mixture were addressed by careful equipment selection, process monitoring, and automation. The approximations of the CSTR fill levels and pumping performance were measured by real-time data from gravimetric balances, ultimately leading to the incorporation of feedback controllers. The introduction of process automation demonstrated in this work resulted in significant improvements in process setpoint consistency, reliability, and spacetime yield, as demonstrated in medium- and large-scale continuous manufacturing runs.

Indexed as

batch designchlorosulfonationcontinuous manufacturingflow chemistryprocess automationpump control system

Identifiers

PMID37241953
PMCPMC10223716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.