Evidence map›Paper›PMID 37241705›Full record

ArticleMicromachines2023

Influence of Aluminum and Copper on Mechanical Properties of Biocompatible Ti-Mo Alloys: A Simulation-Based Investigation.

Omid Ashkani, Mohammad Reza Tavighi, Mojtaba Karamimoghadam, Mahmoud Moradi, Mahdi Bodaghi, Mohammad Rezayat

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 6 institutions in 4 countries.

Omid AshkaniDepartment of Materials Science and Engineering, Faculty of Engineering, Islamic Azad University, Science and Research Branch, Tehran 1477893855, Iran.ORCID 0000-0002-8319-6023
Mohammad Reza TavighiDepartment of Materials Science and Engineering, Faculty of Engineering, Islamic Azad University, Karaj 3149968111, Iran.ORCID 0000-0002-4751-7408
Mojtaba KaramimoghadamDepartment of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy.ORCID 0000-0002-4753-8030
Mahmoud MoradiFaculty of Arts, Science and Technology, University of Northampton, Northampton NN1 5PH, UK.ORCID 0000-0003-2361-4796
Mahdi BodaghiDepartment of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK.ORCID 0000-0002-0707-944X
Mohammad RezayatCenter for Structural Integrity, Micromechanics, and Reliability of Materials (CIEFMA)-Department of Materials Science and Engineering, Universitat Politècnica de Catalunya-BarcelonaTECH, 08019 Barcelona, Spain.ORCID 0000-0003-3929-2664
Islamic Azad University, Karaj · IRIslamic Azad University, Science and Research Branch · IRNottingham Trent University · GBPolytechnic University of Bari · ITUniversitat Politècnica de Catalunya · ESUniversity of Northampton · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of titanium and titanium-based alloys in the human body due to their resistance to corrosion, implant ology and dentistry has led to significant progress in promoting new technologies. Regarding their excellent mechanical, physical and biological performance, new titanium alloys with non-toxic elements and long-term performance in the human body are described today. The main compositions of Ti-based alloys and properties comparable to existing classical alloys (C.P. TI, Ti-6Al-4V, Co-Cr-Mo, etc.) are used for medical applications. The addition of non-toxic elements such as Mo, Cu, Si, Zr and Mn also provides benefits, such as reducing the modulus of elasticity, increasing corrosion resistance and improving biocompatibility. In the present study, when choosing Ti-9Mo alloy, aluminum and copper (Cu) elements were added to it. These two alloys were chosen because one element is considered a favorable element for the body (copper) and the other element is harmful to the body (aluminum). By adding the copper alloy element to the Ti-9Mo alloy, the elastic modulus decreases to a minimum value of 97 GPa, and the aluminum alloy element increases the elastic modulus up to 118 GPa. Due to their similar properties, Ti-Mo-Cu alloys are found to be a good optional alloy to use.

Indexed as

antibacterial titanium alloymetallic biomaterialsimulationTi-9MoTi–xCu–xMo