Fabrication Methods and Chronic In Vivo Validation of Mechanically Adaptive Microfluidic Intracortical Devices.

Youjoung Kim, Natalie N Mueller, William E Schwartzman, Danielle Sarno, Reagan Wynder, George F Hoeferlin, Kaela Gisser, Jeffrey R Capadona, Allison Hess-Dunning

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Effects of Micromachining on Anti-oxidant Elution from a Mechanically-Adaptive Polymer.Journal of micromechanics and microengineering : structures, devices, and systems · 2024
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Youjoung KimDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
Natalie N MuellerDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0003-0336-3686
William E SchwartzmanDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0002-6791-1437
Danielle SarnoDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
Reagan WynderDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0009-0005-6414-7292
George F HoeferlinDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
Kaela GisserDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0009-0004-2223-1157
Jeffrey R CapadonaDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0001-8030-6947
Allison Hess-DunningDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0003-4060-1145

Funding

Integrated Neural Engineering and Rehabilitation Training ProgramT32EB004314 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI Jeffrey R Capadona, Robert F. Kirsch · 2004 to 2026
$6.1M
Hybrid Drug-Eluting Microfluidic Neural Probe for Chronic Drug InfusionI01RX003083 · VA · LOUIS STOKES CLEVELAND VA MEDICAL CENTER · PI CAPADONA, JEFFREY R, DUNNING, ALLISON HESS · 2019 to 2023
–
NIBIB NIH HHS T32 EB004314RRD VA I01 RX003083
6 · The paper itself

Abstract

Intracortical neural probes are both a powerful tool in basic neuroscience studies of brain function and a critical component of brain computer interfaces (BCIs) designed to restore function to paralyzed patients. Intracortical neural probes can be used both to detect neural activity at single unit resolution and to stimulate small populations of neurons with high resolution. Unfortunately, intracortical neural probes tend to fail at chronic timepoints in large part due to the neuroinflammatory response that follows implantation and persistent dwelling in the cortex. Many promising approaches are under development to circumvent the inflammatory response, including the development of less inflammatory materials/device designs and the delivery of antioxidant or anti-inflammatory therapies. Here, we report on our recent efforts to integrate the neuroprotective effects of both a dynamically softening polymer substrate designed to minimize tissue strain and localized drug delivery at the intracortical neural probe/tissue interface through the incorporation of microfluidic channels within the probe. The fabrication process and device design were both optimized with respect to the resulting device mechanical properties, stability, and microfluidic functionality. The optimized devices were successfully able to deliver an antioxidant solution throughout a six-week in vivo rat study. Histological data indicated that a multi-outlet design was most effective at reducing markers of inflammation. The ability to reduce inflammation through a combined approach of drug delivery and soft materials as a platform technology allows future studies to explore additional therapeutics to further enhance intracortical neural probes performance and longevity for clinical applications.

Indexed as

drug deliverymechanically adaptivemicrofabricationmicrofluidicneural interfacepolymer

Identifiers

PMID37241639
PMCPMC10223487

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.