ArticleMicromachines2023
Acoustic Streaming Efficiency in a Microfluidic Biosensor with an Integrated CMUT.
Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The effect of microchannel height on acoustic streaming velocity and capacitive micromachined ultrasound transducer (CMUT) cell damping was investigated. Microchannels with heights ranging from 0.15 to 1.75 mm were used in experiments, and computational microchannel models with heights varying from 10 to 1800 micrometers were simulated. Both simulated and measured data show local minima and maxima of acoustic streaming efficiency associated with the wavelength of the `bulk acoustic wave excited at 5 MHz frequency. Local minima occur at microchannel heights that are multiples of half the wavelength (150 μm), which are caused by destructive interference between excited and reflected acoustic waves. Therefore, microchannel heights that are not multiples of 150 μm are more favorable for higher acoustic streaming effectiveness since destructive interference decreases the acoustic streaming effectiveness by more than 4 times. On average, the experimental data show slightly higher velocities for smaller microchannels than the simulated data, but the overall observation of higher streaming velocities in larger microchannels is not altered. In additional simulation, at small microchannel heights (10-350 μm), local minima at microchannel heights that are multiples of 150 μm were observed, indicating the interference between excited and reflected waves and causing acoustic damping of comparatively compliant CMUT membranes. Increasing the microchannel height to over 100 μm tends to eliminate the acoustic damping effect as the local minima of the CMUT membrane swing amplitude approach the maximum value of 42 nm, which is the calculated amplitude of the freely swinging membrane under the described conditions. At optimum conditions, an acoustic streaming velocity of over 2 mm/s in a 1.8 mm-high microchannel was achieved.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.