Evidence map›Paper›PMID 37241535›Full record

ArticleMicromachines2023

A Fast Soft Continuum Catheter Robot Manufacturing Strategy Based on Heterogeneous Modular Magnetic Units.

Tieshan Zhang, Gen Li, Xiong Yang, Hao Ren, Dong Guo, Hong Wang, Ki Chan, Zhou Ye, Tianshuo Zhao, Chengfei Zhang and 2 more

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Stable magnetic soft structures.Science advances · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Tieshan ZhangThe Robot and Automation Center and the Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong 999077, China.ORCID 0000-0002-7617-6905
Gen LiThe Robot and Automation Center and the Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong 999077, China.
Xiong YangThe Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China.
Hao RenThe Robot and Automation Center and the Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong 999077, China.
Dong GuoThe Robot and Automation Center and the Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong 999077, China.
Hong WangThe Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China.
Ki ChanPrince Philip Dental Hospital, Faculty of Dentistry, University of Hong Kong, Hong Kong 999077, China.
Zhou YeApplied Oral Sciences and Community Dental Care, Faculty of Dentistry, University of Hong Kong, Hong Kong 999077, China.ORCID 0000-0003-4220-0919
Tianshuo ZhaoThe Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong 999077, China.
Chengfei ZhangPrince Philip Dental Hospital, Faculty of Dentistry, University of Hong Kong, Hong Kong 999077, China.
Wanfeng ShangGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0002-3256-3268
Yajing ShenThe Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China.

Funding

National Natural Science Foundation of China 62073308National Natural Science Foundation of China 62273323Shenzhen-Hong Kong-Macau Science and Technology Project SGDX20201103093003017
6 · The paper itself

Abstract

Developing small-scale continuum catheter robots with inherent soft bodies and high adaptability to different environments holds great promise for biomedical engineering applications. However, current reports indicate that these robots meet challenges when it comes to quick and flexible fabrication with simpler processing components. Herein, we report a millimeter-scale magnetic-polymer-based modular continuum catheter robot (MMCCR) that is capable of performing multifarious bending through a fast and general modular fabrication strategy. By preprogramming the magnetization directions of two types of simple magnetic units, the assembled MMCCR with three discrete magnetic sections could be transformed from a single curvature pose with a large tender angle to a multicurvature S shape in the applied magnetic field. Through static and dynamic deformation analyses for MMCCRs, high adaptability to varied confined spaces can be predicted. By employing a bronchial tree phantom, the proposed MMCCRs demonstrated their capability to adaptively access different channels, even those with challenging geometries that require large bending angles and unique S-shaped contours. The proposed MMCCRs and the fabrication strategy shine new light on the design and development of magnetic continuum robots with versatile deformation styles, which would further enrich broad potential applications in biomedical engineering.

Indexed as

biomedical applicationsmagnetic continuum robotsmodular fabricationmodular robots

Identifiers

PMID37241535
PMCPMC10223189

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.