Evidence map›Paper›PMID 37241524›Full record

ArticleMicromachines2023

Hyperelastic Modeling and Validation of Hybrid-Actuated Soft Robot with Pressure-Stiffening.

Majid Roshanfar, Salar Taki, Amir Sayadi, Renzo Cecere, Javad Dargahi, Amir Hooshiar

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Majid RoshanfarMechanical Engineering Department, Concordia University, Montreal, QC H3G 1M8, Canada.ORCID 0000-0003-3738-7782
Salar TakiMechanical Engineering Department, Concordia University, Montreal, QC H3G 1M8, Canada.
Amir SayadiDepartment of Surgery, McGill University, Montreal, QC H3A 0G4, Canada.ORCID 0000-0002-5831-2344
Renzo CecereDepartment of Surgery, McGill University, Montreal, QC H3A 0G4, Canada.ORCID 0000-0003-2611-3698
Javad DargahiMechanical Engineering Department, Concordia University, Montreal, QC H3G 1M8, Canada.ORCID 0000-0002-6198-5080
Amir HooshiarDepartment of Surgery, McGill University, Montreal, QC H3A 0G4, Canada.ORCID 0000-0002-9036-5331

Funding

Fonds de Recherche du Québec - Nature et Technologies n.a.McGill University n.a.McGill University Health Centre n.a.Natural Sciences and Engineering Research Council n.a.
6 · The paper itself

Abstract

Soft robots have gained popularity, especially in intraluminal applications, because their soft bodies make them safer for surgical interventions than flexures with rigid backbones. This study investigates a pressure-regulating stiffness tendon-driven soft robot and provides a continuum mechanics model for it towards using that in adaptive stiffness applications. To this end, first, a central single-chamber pneumatic and tri-tendon-driven soft robot was designed and fabricated. Afterward, the classic Cosserat's rod model was adopted and augmented with the hyperelastic material model. The model was then formulated as a boundary-value problem and was solved using the shooting method. To identify the pressure-stiffening effect, a parameter-identification problem was formulated to identify the relationship between the flexural rigidity of the soft robot and internal pressure. The flexural rigidity of the robot at various pressures was optimized to match theoretical deformation and experiments. The theoretical findings of arbitrary pressures were then compared with the experiment for validation. The internal chamber pressure was in the range of 0 to 40 kPa and the tendon tensions were in the range of 0 to 3 N. The theoretical and experimental findings were in fair agreement for tip displacement with a maximum error of 6.40% of the flexure's length.

Indexed as

Cosserat rod modelhybrid actuationhyperelastic material modelintraluminal applicationspressure-stiffeningsoft robotstiffnesstendon-driven

Identifiers

PMID37241524
PMCPMC10220827

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.