Evidence map›Paper›PMID 37237985›Full record

ArticleAntioxidants (Basel, Switzerland)2023

Quality-by-Design R&D of a Novel Nanozyme-Based Sensor for Saliva Antioxidant Capacity Evaluation.

Riccardo Goldoni, Douglas Vieira Thomaz, Lucanos Strambini, Margherita Tumedei, Paola Dongiovanni, Gaetano Isola, Gianluca Tartaglia

Open access · goldAbstract read
In one paragraph

Article in Antioxidants (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Riccardo GoldoniDepartment of Electronics, Information and Bioengineering (DEIB), Politecnico Di Milano, 20133 Milan, Italy.ORCID 0000-0002-5821-6248
Douglas Vieira ThomazNational Enterprise for NanoScience and NanoTechnology (NEST), Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy.ORCID 0000-0003-0000-3466
Lucanos StrambiniCNR-Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni, 56122 Pisa, Italy.ORCID 0000-0002-4903-4696
Margherita TumedeiDepartment of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20100 Milan, Italy.
Paola DongiovanniMedicine and Metabolic Diseases Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy.ORCID 0000-0003-4343-7213
Gaetano IsolaDepartment of General Surgery and Surgical-Medical Specialties, School of Dentistry, University of Catania, 95124 Catania, Italy.ORCID 0000-0003-4267-6992
Gianluca TartagliaDepartment of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20100 Milan, Italy.
Institute of Electronics, Computer and Telecommunication Engineering · ITUniversity of Milan · ITFondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico · ITIstituto Nanoscienze · ITUniversity of Catania · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Oxidative stress is one of the main causes of cell damage, leading to the onset of several diseases, and antioxidants represent a barrier against the production of reactive species. Saliva is receiving increasing interest as a promising biofluid to study the onset of diseases and assess the overall health status of an individual. The antioxidant capacity of saliva can be a useful indicator of the health status of the oral cavity, and it is nowadays evaluated mainly through spectroscopic methods that rely on benchtop machines and liquid reagents. We developed a low-cost screen-printed sensor based on cerium oxide nanoparticles that can be used to assess the antioxidant capacity of biofluids as an alternative to traditional methods. The sensor development process was investigated via a quality-by-design approach to identify the most critical parameters of the process for further optimization. The sensor was tested in the detection of ascorbic acid, which is used as an equivalent in the assessment of overall antioxidant capacity. The LoDs ranged from 0.1147 to 0.3528 mM, while the recoveries varied from 80% to 121.1%, being therefore comparable with those of the golden standard SAT test, whose recovery value was 96.3%. Therefore, the sensor achieved a satisfactory sensitivity and linearity in the range of clinical interest for saliva and was validated against the state-of-the-art equipment for antioxidant capacity evaluation.

Indexed as

electrochemical sensornanozymequality by designsalivatotal antioxidant capacity

Identifiers

PMID37237985
PMCPMC10215665
OpenAlexW4377107691

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked