Evidence map›Paper›PMID 37237677›Full record

ArticleBioengineering (Basel, Switzerland)2023

Optimized Solutions of Electrocardiogram Lead and Segment Selection for Cardiovascular Disease Diagnostics.

Jiguang Shi, Zhoutong Li, Wenhan Liu, Huaicheng Zhang, Qianxi Guo, Sheng Chang, Hao Wang, Jin He, Qijun Huang

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jiguang ShiSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.
Zhoutong LiHuangpu Branch of Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200011, China.
Wenhan LiuSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.
Huaicheng ZhangSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.ORCID 0000-0002-6874-5530
Qianxi GuoSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.
Sheng ChangSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.ORCID 0000-0003-4875-5501
Hao WangSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.
Jin HeSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.
Qijun HuangSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.ORCID 0000-0001-9679-5191

Funding

National Natural Science Foundation of China 61874079National Natural Science Foundation of China 62074116National Natural Science Foundation of China 81971702
6 · The paper itself

Abstract

Most of the existing multi-lead electrocardiogram (ECG) detection methods are based on all 12 leads, which undoubtedly results in a large amount of calculation and is not suitable for the application in portable ECG detection systems. Moreover, the influence of different lead and heartbeat segment lengths on the detection is not clear. In this paper, a novel Genetic Algorithm-based ECG Leads and Segment Length Optimization (GA-LSLO) framework is proposed, aiming to automatically select the appropriate leads and input ECG length to achieve optimized cardiovascular disease detection. GA-LSLO extracts the features of each lead under different heartbeat segment lengths through the convolutional neural network and uses the genetic algorithm to automatically select the optimal combination of ECG leads and segment length. In addition, the lead attention module (LAM) is proposed to weight the features of the selected leads, which improves the accuracy of cardiac disease detection. The algorithm is validated on the ECG data from the Huangpu Branch of Shanghai Ninth People's Hospital (defined as the SH database) and the open-source Physikalisch-Technische Bundesanstalt diagnostic ECG database (PTB database). The accuracy for detection of arrhythmia and myocardial infarction under the inter-patient paradigm is 99.65% (95% confidence interval: 99.20-99.76%) and 97.62% (95% confidence interval: 96.80-98.16%), respectively. In addition, ECG detection devices are designed using Raspberry Pi, which verifies the convenience of hardware implementation of the algorithm. In conclusion, the proposed method achieves good cardiovascular disease detection performance. It selects the ECG leads and heartbeat segment length with the lowest algorithm complexity while ensuring classification accuracy, which is suitable for portable ECG detection devices.

Indexed as

cardiovascular disease detectionelectrocardiogram (ECG)Genetic Algorithm-Based ECG Leads and Segment Length Optimization (GA-LSLO) frameworkportable ECG detection devices

Identifiers

PMID37237677
PMCPMC10215604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.