Evidence map›Paper›PMID 37237614›Full record

ArticleBioengineering (Basel, Switzerland)2023

Bespoke Implants for Cranial Reconstructions: Preoperative to Postoperative Surgery Management System.

Mihaela-Elena Ulmeanu, Ileana Mariana Mateș, Cristian-Vasile Doicin, Marian Mitrică, Vasile Alin Chirteș, Georgian Ciobotaru, Augustin Semenescu

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Mihaela-Elena UlmeanuFaculty of Industrial Engineering and Robotics, University POLITEHNICA of Bucharest, 060042 Bucharest, Romania.ORCID 0000-0002-6620-7122
Ileana Mariana MateșCentral Military Emergency University Hospital "Dr. Carol Davila", 010825 Bucharest, Romania.
Cristian-Vasile DoicinFaculty of Industrial Engineering and Robotics, University POLITEHNICA of Bucharest, 060042 Bucharest, Romania.
Marian MitricăCentral Military Emergency University Hospital "Dr. Carol Davila", 010825 Bucharest, Romania.
Vasile Alin ChirteșCentral Military Emergency University Hospital "Dr. Carol Davila", 010825 Bucharest, Romania.
Georgian CiobotaruCentral Military Emergency University Hospital "Dr. Carol Davila", 010825 Bucharest, Romania.
Augustin SemenescuFaculty of Materials Science and Engineering, University POLITEHNICA of Bucharest, 060042 Bucharest, Romania.ORCID 0000-0001-6864-3297
Universitatea Națională de Știință și Tehnologie Politehnica București · ROAcademia Oamenilor de Știință din România · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traumatic brain injury is a leading cause of death and disability worldwide, with nearly 90% of the deaths coming from low- and middle-income countries. Severe cases of brain injury often require a craniectomy, succeeded by cranioplasty surgery to restore the integrity of the skull for both cerebral protection and cosmetic purposes. The current paper proposes a study on developing and implementing an integrative surgery management system for cranial reconstructions using bespoke implants as an accessible and cost-effective solution. Bespoke cranial implants were designed for three patients and subsequent cranioplasties were performed. Overall dimensional accuracy was evaluated on all three axes and surface roughness was measured with a minimum value of 2.209 μm for Ra on the convex and concave surfaces of the 3D-printed prototype implants. Improvements in patient compliance and quality of life were reported in postoperative evaluations of all patients involved in the study. No complications were registered from both short-term and long-term monitoring. Material and processing costs were lower compared to a metal 3D-printed implants through the usage of readily available tools and materials, such as standardized and regulated bone cement materials, for the manufacturing of the final bespoke cranial implants. Intraoperative times were reduced through the pre-planning management stages, leading to a better implant fit and overall patient satisfaction.

Indexed as

additive manufacturingbespoke cranial implantcranioplastysurgery management system

Identifiers

PMID37237614
PMCPMC10215819
OpenAlexW4367627209

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.