ArticleBioengineering (Basel, Switzerland)2023
Using Contactless Facial Image Recognition Technology to Detect Blood Oxygen Saturation.
Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Paper-Based Device for the Colorimetric Determination of Glucose in Whole-Blood Samples Using a Smartphone.Bioengineering (Basel, Switzerland) · 2025Article
- Contactless Blood Oxygen Saturation Estimation from Facial Videos Using Deep Learning.Bioengineering (Basel, Switzerland) · 2024Article
- Brave new world: expanding home care in stem cell transplantation and advanced therapies with new technologies.Frontiers in immunology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Since the outbreak of COVID-19, as of January 2023, there have been over 670 million cases and more than 6.8 million deaths worldwide. Infections can cause inflammation in the lungs and decrease blood oxygen levels, which can lead to breathing difficulties and endanger life. As the situation continues to escalate, non-contact machines are used to assist patients at home to monitor their blood oxygen levels without encountering others. This paper uses a general network camera to capture the forehead area of a person's face, using the RPPG (remote photoplethysmography) principle. Then, image signal processing of red and blue light waves is carried out. By utilizing the principle of light reflection, the standard deviation and mean are calculated, and the blood oxygen saturation is computed. Finally, the effect of illuminance on the experimental values is discussed. The experimental results of this paper were compared with a blood oxygen meter certified by the Ministry of Health and Welfare in Taiwan, and the experimental results had only a maximum error of 2%, which is better than the 3% to 5% error rates in other studies The measurement time was only 30 s, which is better than the one minute reported using similar equipment in other studies. Therefore, this paper not only saves equipment expenses but also provides convenience and safety for those who need to monitor their blood oxygen levels at home. Future applications can combine the SpO2 detection software with camera-equipped devices such as smartphones and laptops. The public can detect SpO2 on their own mobile devices, providing a convenient and effective tool for personal health management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.