Evidence map›Paper›PMID 37234957›Full record

ArticleFrontiers in surgery2023

Postoperative hip center position is associated with gait symmetry in range of axial rotation in dysplasia patients after THA.

Yi Hu, Diyang Zou, Mengda Jiang, Qingyu Qian, Huiwu Li, Tsung-Yuan Tsai, Jingwei Zhang

Abstract read
In one paragraph

Article in Frontiers in surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yi Hu *Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Diyang Zou *Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Mengda JiangDepartment of Radiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Qingyu QianDepartment of Radiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Huiwu LiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Tsung-Yuan TsaiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Jingwei ZhangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study aimed to explore whether pre- or postoperative hip structures or surgical changes significantly influence hip range of motion (ROM) symmetry in patients with hip dysplasia during gait after total hip arthroplasty (THA) and provide possible surgical suggestions. Methods: Fourteen patients with unilateral hip dysplasia underwent computed tomography before and after surgery to create three-dimensional hip models. Pre- and postoperative acetabular and femoral orientations, hip rotation centers (HRC), and femoral lengths were measured. Bilateral hip ROM during level walking after THA was quantified using dual fluoroscopy. The ROM symmetry in flexion-extension, adduction-abduction, and axial rotation was calculated using the symmetry index (SI). The relationship between SI and the above anatomical parameters and demographic characteristics was tested using Pearson's correlation and linear regression. Results: The average SI values for flexion-extension, adduction-abduction, and axial rotation during gait were -0.29, -0.30, and -0.10, respectively. Significant correlations were detected mainly in the postoperative HRC position. A distally placed HRC was associated with increased SI values for adduction-abduction ( Conclusions: Postoperative HRC position was significantly correlated with gait symmetry in the frontal and transverse planes in patients with unilateral hip dysplasia after THA. Surgical reconstruction of the HRC to between 17 mm medially and 16 mm laterally may contribute to gait symmetry.

Indexed as

developmental hip dysplasia (DDH)fluoroscopegait symmetryhip centertotal hip arthroplasty

Identifiers

PMID37234957
PMCPMC10206229

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.