Evidence map›Paper›PMID 37233584›Full record

ArticleMembranes2023

Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood.

Kun Wang, Hyang Seol, Alex Cheng, Nash McKeague, Megan Carlson, Wade Degraff, Sijia Huang, Sangil Kim

Open access · goldAbstract read
In one paragraph

Article in Membranes, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Kun WangDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
Hyang SeolDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
Alex ChengDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
Nash McKeagueDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
Megan CarlsonDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.ORCID 0009-0001-5837-0464
Wade DegraffDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
Sijia HuangLawrence Livermore National Laboratory, Livermore, CA 94550, USA.
Sangil KimDepartment of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.ORCID 0000-0002-5797-2703
University of Illinois Chicago · USLawrence Livermore National Laboratory · US

Funding

University of Illinois at Chicago CTRI-2-200258-709000-709017
6 · The paper itself

Abstract

Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.

Indexed as

plasma separationpoint-of-care deviceportable plasma separation deviceviral load testszwitterionic membrane

Identifiers

PMID37233584
PMCPMC10223665
OpenAlexW4377020896

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.