Evidence map›Paper›PMID 37232909›Full record

ArticleBiosensors2023

Wearable Triboelectric Nanogenerator with Ground-Coupled Electrode for Biomechanical Energy Harvesting and Sensing.

Kangyu Su, Xiaobo Lin, Zhangwei Liu, Yun Tian, Zhengchun Peng, Bo Meng

Abstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kangyu SuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Xiaobo LinKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Zhangwei LiuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Yun TianKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Zhengchun PengKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID 0000-0002-7114-1797
Bo MengKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID 0000-0003-0457-7942

Funding

National Natural Science Foundation of China 61904111Natural Science Foundation of Guangdong Province 2020A1515011487Science and Technology Innovation Commission of Shenzhen 20200810103814002, KQTD20170810105439418
6 · The paper itself

Abstract

Harvesting biomechanical energy for electricity as well as physiological monitoring is a major development trend for wearable devices. In this article, we report a wearable triboelectric nanogenerator (TENG) with a ground-coupled electrode. It has a considerable output performance for harvesting human biomechanical energy and can also be used as a human motion sensor. The reference electrode of this device achieves a lower potential by coupling with the ground to form a coupling capacitor. Such a design can significantly improve the TENG's outputs. A maximum output voltage up to 946 V and a short-circuit current of 36.3 μA are achieved. The quantity of the charge that transfers during one step of an adult walking reaches 419.6 nC, while it is only 100.8 nC for the separate single-electrode-structured device. In addition, using the human body as a natural conductor to connect the reference electrode allows the device to drive the shoelaces with integrated LEDs. Finally, the wearable TENG is able to perform motion monitoring and sensing, such as human gait recognition, step count and movement speed calculation. These show great application prospects of the presented TENG device in wearable electronics.

Indexed as

ElectricityWearable Electronic DevicesAdultElectrodesElectronicsHumansMotionbiomechanical energy harvestinghuman motion monitoringtriboelectric nanogeneratorwearable sensor

Identifiers

PMID37232909
PMCPMC10216270

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.