ArticleDentistry journal2023
Therapy for Temporomandibular Disorders: 3D-Printed Splints from Planning to Evaluation.
Article in Dentistry journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Fully digital workflow versus conventional methods for fabricating the Michigan appliance in patients with temporomandibular joint disorder. A randomized controlled clinical trial.BMC oral health · 2026Trial
- Application of fully digital occlusal splints in painful temporomandibular disorders: a randomized controlled clinical study.Head & face medicine · 2026Trial
- Comparative Efficacy of Digital 3D-Printed and Conventional Stable Occlusal Splints in the Treatment of Temporomandibular Disorders.Journal of oral rehabilitation · 2025Trial
- Accuracy and Reproducibility of Digital Vertical Dimension Increase in Occlusal Splint Design: A Comparative In Vitro Study of Three CAD Software Systems.Dentistry journal · 2026Article
- Impact of Printing Orientation and Printer Type on the Accuracy of 3D-Printed Dental Splints.Materials (Basel, Switzerland) · 2026Article
- Behavioral Dentistry in the Digital Age: A Review of Biofeedback Occlusal Splint Therapy.Cureus · 2026Review
- A retrospective evaluation of the clinical efficacy of occlusal splint therapy combined with manual therapy in patients with anterior disc displacement without reduction.Journal of oral & facial pain and headache · 2025Article
- Three-Dimensionally Printed Splints in Dentistry: A Comprehensive Review.Dentistry journal · 2025Review
- Review
- Digital Occlusion Tracking by T-Scan Novus System in Bruxism Patients Treated With 3D Printed Occlusal Splints.International journal of dentistry · 2025Article
- Case Report: A comprehensive digital workflow to enhance predictability and precision with fixed dental prostheses in the posterior region.Frontiers in dental medicine · 2025Article
- Comparative Evaluation of Temporomandibular Disorders and Dental Wear in Video Game Players.Journal of clinical medicine · 2024Article
- Three-Dimensionally-Printed Polymer and Composite Materials for Dental Applications with Focus on Orthodontics.Polymers · 2024Review
- Clinical effect of digitalized designed and 3D-printed repositioning splints in the treatment of anterior displacement of temporomandibular joint disc.BMC musculoskeletal disorders · 2024Article
- Literature Review of an Anterior Deprogrammer to Determine the Centric Relation and Presentation of Cases.Bioengineering (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThis article describes the authors' digital workflow-based method for fabricating intraoral occlusal splints, from planning to the evaluation phase. MATERIALS AND
methodsIn our protocol, first, we had a registration phase. This included taking digital impressions, determining the centric relation (CR) position with the deprogrammer Luci Jig, and using the digital facebow for measuring the individual values. The laboratory phase was next, which included planning and manufacturing with a 3D printer. The last phase was delivery, when we checked the stability of the splint and adjusted the occlusal part.
resultThe average cost is lower for a fully digital splint than for conventional methods. In terms of time, there was also a significant difference between the classic and digital routes. From a dental technical point of view, the execution was much more predictable. The printed material was very rigid and, therefore, fragile. Compared to the analog method, the retention was much weaker.
conclusionThe presented method permits time-efficient laboratory production, and may also be performed chairside in a dental office. The technology is perfectly applicable to everyday life. In addition to its many beneficial properties, its negative properties must also be highlighted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials