Evidence map›Paper›PMID 37231426›Full record

ArticleBMC oral health2023

Influence of design implant and apical depth in post-extraction sockets: an in vitro simulated study.

Marcelo Sales Cavalcante, Marcelo Ferraro-Bezerra, Paulo Goberlanio de Barros Silva, Gabriel Silva Andrade, Phillipe Nogueira Barbosa Alencar, Josfran da Silva Ferreira Filho, Lucas Alexandre Maia, Raul Anderson Domingues Alves da Silva, Danna Mota Moreira, Rafael Linard Avelar

Abstract read
In one paragraph

Article in BMC oral health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Marcelo Sales CavalcanteSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Marcelo Ferraro-BezerraDepartment of Clinical Dentistry, Oral and Maxillofacial Surgery Service, Federal University of Ceará, Walter Cantídio University Hospital, Fortaleza, Brazil.
Paulo Goberlanio de Barros SilvaSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Gabriel Silva AndradeSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Phillipe Nogueira Barbosa AlencarSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Josfran da Silva Ferreira FilhoOral and Maxillofacial Surgery Resident at Institute Jose Frota Hospital, Fortaleza, Brazil.
Lucas Alexandre MaiaSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Raul Anderson Domingues Alves da SilvaSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Danna Mota MoreiraSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
Rafael Linard AvelarSchool of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil. rafael.avelar@unichristus.edu.br.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImplant design and apical stability are principal parameters involved in achieving successful primary stability. Using polyurethane models to simulate post-extraction sockets, we investigated the effects of using differing blade designs on the primary stability of tapered implants and the impact of apical depth.

methodSix polyurethane blocks were used to simulate post-extraction pockets. One of the implants presented self-tapping blades (Group A), while the other (Group B) did not. Seventy-two implants were placed at 3 different depths (5 mm, 7 mm, and 9 mm), and a torque wrench was used to measure the stability of the implants.

resultsWhen evaluating the implants (placed at 5 mm, 7 mm, and 9 mm apical to the socket), we observed that the torque of the Group B implants was higher than that of Group A implants (P < 0.01). At the 9-mm depth, there was no difference between the groups (Drive GM 34.92 Ncm and Helix GM 32.33 Ncm) (P > 0.001), and considering the same implant groups, those placed at 7-mm and 9-mm depths presented higher torques (p < 0.01) than those placed at 5-mm (p > 0.01).

conclusionConsidering both groups, we concluded that an insertion depth of greater than 7 mm is needed for initial stability, and in situations involving reduced supportive bone tissue or low bone density, a non-self-tapping thread design improves implant stability.

Indexed as

Dental Implantation, EndosseousDental ImplantsDental CareDental Prosthesis DesignHumansPolyurethanesTooth SocketTorqueDental ImplantsPolyurethanesDesignImplantInitial stabilityTapered implants

Identifiers

PMID37231426
PMCPMC10214678

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.