Evidence map›Paper›PMID 37227572›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Feasibility of tracked ultrasound registration for pelvic-abdominal tumor navigation: a patient study.

M A J Hiep, W J Heerink, H C Groen, T J M Ruers

Registry-linked trialOpen access · greenAbstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05637359 (Tracked Ultrasound for Patient Registration in Surgical Navigation During Abdominal Cancer Surgery), which is not on this map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05637359 completednot on this map

Tracked Ultrasound for Patient Registration in Surgical Navigation During Abdominal Cancer Surgery

Typeobservational_patient_registrySponsorThe Netherlands Cancer InstituteRan2020 to 2021Enrolled26ConditionsAbdominal CancerArmsTracked ultrasound measurement
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Performance of a tracked ultrasound navigation setup for pediatric tumor surgery: a phantom study.International journal of computer assisted radiology and surgery · 2026
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

M A J HiepDepartment of Surgical Oncology, Netherlands Cancer Institute, 1066 CX, Amsterdam, The Netherlands. ma.hiep@nki.nl.ORCID http://orcid.org/0000-0002-7362-8515
W J HeerinkDepartment of Surgical Oncology, Netherlands Cancer Institute, 1066 CX, Amsterdam, The Netherlands.
H C GroenDepartment of Surgical Oncology, Netherlands Cancer Institute, 1066 CX, Amsterdam, The Netherlands.
T J M RuersDepartment of Surgical Oncology, Netherlands Cancer Institute, 1066 CX, Amsterdam, The Netherlands.
The Netherlands Cancer Institute · NL

Funding

KWF Kankerbestrijding Institutional grantMinisterie van Volksgezondheid, Welzijn en Sport Institutional grant
6 · The paper itself

Abstract

purposeSurgical navigation techniques can guide surgeons in localizing pelvic-abdominal malignancies. For abdominal navigation, accurate patient registration is crucial and is generally performed using an intra-operative cone-beam CT (CBCT). However, this method causes 15-min surgical preparation workflow interruption and radiation exposure, and more importantly, it cannot be repeated during surgery to compensate for large patient movement. As an alternative, the accuracy and feasibility of tracked ultrasound (US) registration are assessed in this patient study.

methodsPatients scheduled for surgical navigation during laparotomy of pelvic-abdominal malignancies were prospectively included. In the operating room, two percutaneous tracked US scans of the pelvic bone were acquired: one in supine and one in Trendelenburg patient position. Postoperatively, the bone surface was semiautomatically segmented from US images and registered to the bone surface on the preoperative CT scan. The US registration accuracy was computed using the CBCT registration as a reference and acquisition times were compared. Additionally, both US measurements were compared to quantify the registration error caused by patient movement into Trendelenburg.

resultsIn total, 18 patients were included and analyzed. US registration resulted in a mean surface registration error of 1.2 ± 0.2 mm and a mean target registration error of 3.3 ± 1.4 mm. US acquisitions were 4 × faster than the CBCT scans (two-sample t-test P < 0.05) and could even be performed during standard patient preparation before skin incision. Patient repositioning in Trendelenburg caused a mean target registration error of 7.7 ± 3.3 mm, mainly in cranial direction.

conclusionUS registration based on the pelvic bone is accurate, fast and feasible for surgical navigation. Further optimization of the bone segmentation algorithm will allow for real-time registration in the clinical workflow. In the end, this would allow intra-operative US registration to correct for large patient movement.

trial registrationThis study is registered in ClinicalTrials.gov (NCT05637359).

Indexed as

Abdominal NeoplasmsPelvic NeoplasmsSurgery, Computer-AssistedFeasibility StudiesHumansImaging, Three-DimensionalTomography, X-Ray ComputedUltrasonographyBoneElectromagnetic trackingPelvic malignanciesRegistrationSurgical navigationUltrasound

Identifiers

PMID37227572
OpenAlexW4378173088

What OpenQuestion holds

Textmetadata
Read underepoch 390