Evidence map›Paper›PMID 37226558›Full record

ArticleOrthopaedic surgery2023

Novel Claw-shaped Bone Plate in Complex Unstable Scapular Neck and Body Fractures: Comparison with Reconstruction Locking Plate.

Huiming Shi, Kun Zhang, Yuanjun Hu, Wei Wu, Ning Liu, Haixia Lu

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Minimally Invasive Combined Medial and Lateral Approach for Treating Displaced Scapular Body and Neck Fractures.Medical science monitor : international medical journal of experimental and clinical research · 2024
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Huiming ShiSchool of Basic Medical Sciences, Xi'an Jiaotong University, Xi'an, China.ORCID https://orcid.org/0000-0002-3300-0627
Kun ZhangOrthopaedics Department of Xi'an Honghui Hospital, Xi'an, China.
Yuanjun HuTraumatic Orthopaedics Department, Hanzhong Central Hospital, Hanzhong, China.
Wei WuTraumatic Orthopaedics Department, Hanzhong Central Hospital, Hanzhong, China.
Ning LiuTraumatic Orthopaedics Department, Hanzhong Central Hospital, Hanzhong, China.
Haixia LuSchool of Basic Medical Sciences, Xi'an Jiaotong University, Xi'an, China.
Hanzhong Central Hospital · CNXi'an Honghui Hospital · CNXi'an Jiaotong University · CN

Funding

Health and Family Planning Research Fund Project of Shaanxi Province 2016C005Science and Technology Project of Hanzhong YK2017
6 · The paper itself

Abstract

objectiveFor complex and unstable scapular fractures requiring simultaneous fixation of the glenoid neck, the lateral margin of the body, and/or the scapular diaphysis, reconstruction locking plate is difficult to achieve satisfactory fixation. In order to optimize the fixation effect, the newly designed claw-shaped bone plate was designed for fixing such fractures. We also evaluate the clinical effects and follow-up at an average of 1 year after treatment in scapular internal fixation by using reconstruction locking plate and claw-shaped bone plate in complex unstable scapular body and glenoid neck fracture.

methodsA retrospective study was conducted from 2018 to 2021, thirty-three patients (27 males and six females) who were defined unstable scapular fractures by Ada-Miller. Fifteen patients (52.86 ± 8.26 years) received claw-shaped bone plate and 18 cases (51.61 ± 11.31 years) received reconstruction locking plate with the intermuscular approach. The clinical effect was evaluated based on the operation time, intraoperative blood loss, surgical complications, clinical healing time and Constant-Murley score (CMS). The data analysis by Student t, Mann-Whitney U test and Pearson's chi squared test.

resultsCompared with reconstruction locking plate, the claw-shaped bone plate showed shorter operation time (102.73 ± 18.43 min vs. 156 ± 37.53, P < 0.0001), higher CMS (94.00 ± 4.07 vs. 89.88 ± 5.42, P = 0.02) and no differences between the two groups regarding intraoperative blood loss (208.00 ± 96.45 mL vs. 269.44 ± 120.21, P = 0.12) and clinical healing times (9.96 ± 1.52 vs. 10.05 ± 1.67, P = 0.87). Follow-up were conducted at first, third, 6 and 12 months after surgery. The operation was successful in all patients with no intraoperative complications.

conclusionsFor the treatment of complex and unstable scapular neck body fractures, the application of claw-shaped bone plate demonstrated short operation time, better stability of the fracture block, and higher CMS. In the intraoperative and postoperative follow-up showed better clinical results and rehabilitation effects.

Indexed as

Fractures, BoneShoulder FracturesBlood Loss, SurgicalBone PlatesFemaleFracture Fixation, InternalHumansMaleRetrospective StudiesTreatment OutcomeClaw-shaped bone plateIntermuscular approach operationOsteosynthesisPlateScapula fracture

Identifiers

PMID37226558
PMCPMC10432470
OpenAlexW4378173521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.