Evidence map›Paper›PMID 37226516›Full record

ArticleProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine2023

A geometric assessment method for estimating dimensional change of retrieved dual mobility liners for total hip arthroplasty.

Mackenzie Smeeton, Graham Isaac, Ruth Wilcox, James Anderson, Tim Board, Douglas W Van Citters, Sophie Williams

Abstract read
In one paragraph

Article in Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. A geometric assessment method for estimating dimensional change of retrieved dual mobility liners for total hip arthroplasty.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mackenzie SmeetonInstitute of Medical and Biological Engineering, University of Leeds, Leeds, UK.ORCID 0000-0001-7639-1368
Graham IsaacInstitute of Medical and Biological Engineering, University of Leeds, Leeds, UK.
Ruth WilcoxInstitute of Medical and Biological Engineering, University of Leeds, Leeds, UK.
James AndersonDePuy Synthes Joint Reconstruction, Leeds, UK.
Tim BoardWrightington, Wigan and Leigh NHS Foundation Trust, Wigan, UK.
Douglas W Van CittersDartmouth College, Thayer School of Engineering, Hanover, NH, USA.
Sophie WilliamsInstitute of Medical and Biological Engineering, University of Leeds, Leeds, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Despite their emerging use, the current understanding of the in-vivo functional mechanisms of Dual Mobility (DM) Total Hip Replacements (THRs) is poor, and current characterisation methodologies are not suitable for the unique function and design of these types of devices. Therefore, the aim of this study was to develop a geometric characterisation methodology to estimate dimensional change across the articulating surfaces of retrieved DM polyethylene liners so that their invivo function may be better understood. The method involves the acquisition of three-dimensional coordinate data from the internal and external surfaces of DM liners. The data is processed using a bespoke MATLAB script which approximates the unworn reference geometry of each surface, calculates geometric variance at each point and produces surface deviation heatmaps so that areas of wear and/or deformation may be visualised across the implant. One as-manufactured and five retrieved DM liners were assessed, which demonstrated the efficacy, repeatability and sensitivity of the developed method. This study describes an automated and non-destructive approach for assessing retrieved DM liners of any size and from any manufacturer, which may be used in future research to improve our understanding of their in-vivo function and failure mechanisms.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisHumansPolyethyleneProsthesis DesignProsthesis FailurePolyethylenecoordinate measuring machinedual mobilityexplant analysisgeometric assessmentTotal hip replacement

Identifiers

PMID37226516
PMCPMC10291107

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.