Evidence map›Paper›PMID 37223709›Full record

ArticleHeliyon2023

Electrochemical study of the effect of radiofrequency on glutamate oxidase activity using a glutamate oxidase-based biosensor.

Faezeh Faraji, Hassan Tavakoli, Mahvash Jafari, Akram Eidi, Adeleh Divsalar

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Faezeh FarajiDepartment of Biology, Faculty of Basic Sciences, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Hassan TavakoliRadiation Injuries Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran.
Mahvash JafariDepartment of Biochemistry, Faculty of Medicine, Baqiyatallah University of Medical Sciences, Tehran, Iran.
Akram EidiDepartment of Biology, Faculty of Basic Sciences, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Adeleh DivsalarDepartment of Cell and Molecular Sciences, Faculty of Biological Sciences Kharazmi University, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A biosensor based on glutamate oxidase (GluOx) was developed to measure glutamate concentration. The main function of this type of biosensor is related to the structure and catalytic activity of GluOx. Since radiofrequency, as the widest spectrum of electromagnetic fields, can affect the catalytic activity and structure of GluOx, in this study, the effect of these fields on the analytical parameters of the fabricated biosensor was investigated. To build the biosensor a sol-gel solution of chitosan and native GluOx were prepared and then immobilized on the surface of the platinum electrode. Similarly, to investigate the effect of radiofrequency fields on the analytical parameters of the biosensor, instead of the native GluOx, irradiated GluOx was used to build the biosensor. To evaluate the biosensor responses, cyclic voltammetry experiments were performed and voltammograms were considered as biosensor responses. To determine the analytical parameters including detection limit, linear range, and saturation region of the responses, calibration curves were drawn for each of the biosensors. Also the long-term stability and selectivity of the fabricated biosensor were evaluated. Thereafter, the optimum pH and temperature for each of these two biosensors were examined. The results showed that radiofrequency waves harmed the detection and response of biosensors in the saturation region, while they had little effect on the linear region. Such results could be due to the effect of radiofrequency waves on the structure and function of glutamate oxidase. In general, the results indicate that when a glutamate oxidase-based biosensor is used to measure glutamate in radiofrequency fields, corrective coefficients for this type of biosensor should be considered to accurately measure glutamate concentration.

Indexed as

Analytical parametersBiosensorGlutamateGlutamate oxidaseRadiofrequency

Identifiers

PMID37223709
PMCPMC10200849

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.