Evidence map›Paper›PMID 37221854›Full record

SynthesisInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026

Single antiplatelet regimen in flow diverter treatment of cerebral aneurysms: The drug matters. A systematic review and meta-analysis.

Yihui Ma, Jawid Madjidyar, Tilman Schubert, Patrick Thurner, Isabelle Barnaure, Zsolt Kulcsar

Open access · hybridAbstract readSystematic ReviewMeta-Analysis
In one paragraph

Synthesis in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Short to mid-term outcomes of flow re-direction endoluminal device X (FREDDiagnostic and interventional radiology (Ankara, Turkey) · 2026
    Pooled it
  3. Article
  4. Article
  5. High mesh density flow diversion of upper basilar artery aneurysms: Experience in 23 cases.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Yihui MaDepartment of Neurosurgery, Zhongnan Hospital of Wuhan University, Wuhan, China.ORCID 0009-0004-5649-6903
Jawid MadjidyarDepartment of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Tilman SchubertDepartment of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Patrick ThurnerDepartment of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Isabelle BarnaureDepartment of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.ORCID 0000-0003-4052-4899
Zsolt KulcsarDepartment of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
University of Zurich · CHWuhan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundHemorrhagic and thromboembolic complications (TECs) are the main concerns in the endovascular treatment of intracranial aneurysms using flow diverter devices (FDs). The clinical demand for single antiplatelet therapy (SAPT) is increasing especially with the development of devices with lower thrombogenicity profile. However, the safety of SAPT is not well established.ObjectiveTo analyze the safety and efficacy of SAPT in terms of ischemic and hemorrhagic complications in patients undergoing FDs treatment for cerebral aneurysms.MethodsA systematic literature search and meta-analysis were conducted in PubMed, Ovid MEDLINE, Ovid Embase, and Web of Science from January 2010 until October 2022. Twelve articles which reported SAPT and data on hemorrhagic, TECs, and mortality following FDs treatment were included.ResultsOverall, the 12 studies involved 237 patients with 295 aneurysms. Five investigated the safety and efficacy of SAPT in 202 unruptured aneurysms. Six studies focused on 57 ruptured aneurysms. One study included both ruptured and unruptured aneurysms. Among the 237 patients, prasugrel was most often used as SAPT in 168 cases (70.9%), followed by aspirin in 42 (17.7%) patients, and by ticagrelor in 27 (11.4%). Overall, the hemorrhagic complication rate was 0.1% (95% CI 0% to 1.8%). The TEC rate was 7.6% (95% CI 1.7% to 16.1%). In the subgroup analysis, the TEC rates of prasugrel monotherapy of 2.4% (95% CI 0% to 9.3%) and ticagrelor monotherapy of 4.2% (95% CI 0.1% to 21.1%) were lower than of aspirin monotherapy 20.2% (95% CI 5.9% to 38.6%). The overall mortality rate was 1.3% (95% CI 0% to 6.1%).ConclusionAccording to the available data, SAPT regimen in patients undergoing FDs treatment for cerebral aneurysms has an acceptable safety profile, especially with the use of ADP-receptor antagonists.

Indexed as

Endovascular ProceduresIntracranial AneurysmPlatelet Aggregation InhibitorsStentsAspirinHumansTreatment OutcomeAspirinPlatelet Aggregation InhibitorsFlow diverter deviceshemorrhagic complicationsintracranial aneurysmssingle antiplatelet therapythromboembolic complications

Identifiers

PMID37221854
PMCPMC13294523
OpenAlexW4377940207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.