Evidence map›Paper›PMID 37219422›Full record

ArticleJournal of clinical microbiology2023

Evaluation of Three Automated Nontreponemal Rapid Plasma Reagin (RPR) Tests for the Laboratory Diagnosis of Syphilis.

Mayur R Shukla, Lara Pereira, Anne M Gaynor, Yongcheng Sun, Daniel Edwards, Tamara Simmons, Curtis W Andrews, Ina U Park, Jaeyoung Hong, Weiping Cao and 2 more

Open access · greenAbstract read
In one paragraph

Article in Journal of clinical microbiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Review
  3. Update on syphilis diagnostics.Current opinion in infectious diseases · 2025
    Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 5 institutions in 1 country.

Mayur R ShuklaDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.ORCID 0000-0003-4378-6288
Lara PereiraDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Anne M GaynorAssociation of Public Health Laboratories, Silver Spring, Maryland, USA.
Yongcheng SunDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Daniel EdwardsOklahoma State Department of Health, Oklahoma City, Oklahoma, USA.
Tamara SimmonsGeorgia Public Health Laboratory, Decatur, Georgia, USA.
Curtis W AndrewsAlabama Department of Public Health, Mobile, Alabama, USA.
Ina U ParkDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Jaeyoung HongDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Weiping CaoDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Ellen N KershDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.ORCID 0000-0003-3819-0324
Yetunde FakileDivision of STD Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Centers for Disease Control and Prevention · USAlabama Department of Public Health · USAssociation of Public Health Laboratories · USGeorgia Department of Public Health · USOklahoma State Department of Health · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Automated nontreponemal rapid plasma reagin (RPR) tests were recently introduced in the United States for syphilis testing and limited performance data are available. In collaboration with the Association of Public Health Laboratories, three public health laboratories (PHL) were chosen through a competitive selection process to evaluate the performance of three FDA-cleared automated RPR test systems: BioPlex 2200 Syphilis Total & RPR assay (Bio-Rad Laboratories), AIX 1000 (Gold Standard Diagnostics), and ASI Evolution (Arlington Scientific). Panels prepared at the CDC included: a qualitative panel comprised of 734 syphilis reactive/nonreactive sera; a quantitative panel of 50 syphilis reactive sera (RPR titer 1:64 to 1:1,024); and a reproducibility panel of 15 nonreactive and reactive sera (RPR titer 1:1 to 1:64). Panels were shipped frozen to the PHL and tested on the automated RPR systems following manufacturers' instructions. Prior test results were blinded to all laboratories. When compared to manual RPR (Arlington Scientific) performed at the CDC as a reference test, the qualitative panel results demonstrated an overall concordance of 95.9% for AIX 1000, 94.6% for ASI Evolution, and 92.6% for Bioplex RPR; quantitative panel showed within range titer of 2-fold for 94% of specimens for AIX 1000, 68% for ASI Evolution, and 64% for BioPlex RPR, and the reproducibility testing panel demonstrated point estimates ranging from 69 to 95%. Automated RPR instruments could reduce turnaround time and minimize interpretation errors. However, additional evaluations with more specimens could assist laboratories with implementing automated RPR tests and understanding their limitations.

Indexed as

SyphilisAntibodies, BacterialHumansReaginsReproducibility of ResultsSyphilis SerodiagnosisTreponema pallidumAntibodies, BacterialReaginsautomated RPRnontreponemalsyphilis

Identifiers

PMID37219422
PMCPMC10281131
OpenAlexW4377564850

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.