ArticleAnalytical chemistry2023
Effect of Humidity on the Mobilities of Small Ions in Ion Mobility Spectrometry.
Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Identification of Bacteria and Viruses by Pyrolysis-Gas Chromatography-Ion Mobility Spectrometry.Analytical chemistry · 2026Article
- Analytical Challenges and Strategies for Compound Identification Using Gas Chromatography-Ion Mobility Spectrometry.Analytical chemistry · 2026Article
- Dual Ionization Ion-Mobility Mass Spectrometry Hyphenated with Catalytic Oxygenation-Mediated Extraction.ACS measurement science au · 2026Article
- Exploring Field-Induced Fragmentation of Protonated Alcohols: Mechanistic Insights and Stabilizing Ion-Solvent Clusters.Journal of the American Society for Mass Spectrometry · 2026Article
- Article
- Innovative Supported Membranes for Ion Mobility Spectrometer (IMS) Sample Introduction Systems with High Permeability Relative to Toxic Agents in Air (TAAs).Materials (Basel, Switzerland) · 2025Article
- Conservation of the Charge in Signal from Drift Tube Ion Mobility Spectrometers.Analytical chemistry · 2024Article
- On the Arrival Time Distribution of Reacting Systems in Ion Mobility Spectrometry.Analytical chemistry · 2024Article
Corrections and comments
- Erratum issued
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Ions in the ion mobility spectrometry (IMS) are mostly hydrated. A single peak in the drift time spectrum is usually generated by a mixture of ions differing in the number of attached water molecules. Under real IMS detector operating conditions, ions change their composition during movement in the drift region due to the changes in the number of water molecules attached to the ion. The impact of water vapor on the drift times of small ions at different temperatures was studied experimentally using an ion mobility spectrometer. The experiments were carried out for hydronium, ammonium, oxygen, chloride, bromide, and iodide ions. A theoretical model was developed, allowing us to calculate the effective mobility of ions for a given concentration of water vapor and temperature. The basic assumption adopted in this model was the linear dependence of the effective mobility coefficient on the mobility of ions with a certain degree of hydration. The weighting factors in this relationship are the abundances of individual types of ions. These parameters were determined by calculations based on the thermodynamics of the formation and disintegration of ionic clusters. From the known values of temperature, pressure, and humidity, the values of effective mobilities can be predicted quite accurately. The dependencies of reduced mobilities on the average degree of hydration were also determined. For these dependencies, the measurement points on the graphs are gathered along specific lines. This means that the average degree of hydration unambiguously determines the value of reduced mobility for a given type of ions.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.