ArticleBMJ open quality2023

Implementation of barcode medication administration (BMCA) technology on infusion pumps in the operating rooms.

Manon Hogerwaard, Muriël Stolk, Liselotte van Dijk, Mariët Faasse, Nico Kalden, Sanne Elisabeth Hoeks, Roland Bal, Maarten Ter Horst

Abstract read
In one paragraph

Article in BMJ open quality, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Using Safety-I, II, and III to level up patient safety.Current opinion in anaesthesiology · 2025
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Manon HogerwaardAnesthesiology, Erasmus MC, Rotterdam, The Netherlands.
Muriël StolkQuality and Patientcare, Erasmus MC, Rotterdam, The Netherlands.
Liselotte van DijkQuality and Patientcare, Erasmus MC, Rotterdam, The Netherlands.
Mariët FaasseAnesthesiology, Erasmus MC, Rotterdam, The Netherlands.
Nico KaldenDepartment of Medical Technology/I&T, Erasmus MC, Rotterdam, The Netherlands.
Sanne Elisabeth HoeksAnesthesiology, Erasmus MC, Rotterdam, The Netherlands.
Roland BalSchool of Health Policy & Management, Erasmus Universiteit, Rotterdam, The Netherlands.
Maarten Ter HorstAnesthesiology, Erasmus MC, Rotterdam, The Netherlands m.terhorst@erasmusmc.nl.ORCID 0000-0002-4990-4620

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMedication administration errors (MAEs) are a major cause of morbidity and mortality. An updated barcode medication administration (BCMA) technology on infusion pumps is implemented in the operating rooms to automate double check at a syringe exchange.

objectiveThe aim of this mixed-methods before-and-after study is to understand the medication administrating process and assess the compliance with double check before and after implementation.

methodsReported MAEs from 2019 to October 2021 were analysed and categorised to the three moments of medication administration: (1) bolus induction, (2) infusion pump start-up and (3) changing an empty syringe. Interviews were conducted to understand the medication administration process with functional resonance analysis method (FRAM). Double check was observed in the operating rooms before and after implementation. MAEs up to December 2022 were used for a run chart.

resultsAnalysis of MAEs showed that 70.9% occurred when changing an empty syringe. 90.0% of MAEs were deemed to be preventable with the use of the new BCMA technology. The FRAM model showed the extent of variation to double check by coworker or BCMA.Observations showed that the double check for pump start-up changed from 70.2% to 78.7% postimplementation (p=0.41). The BCMA double check contribution for pump start-up increased from 15.3% to 45.8% (p=0.0013). The double check for changing an empty syringe increased from 14.3% to 85.0% (p<0.0001) postimplementation. BCMA technology was new for changing an empty syringe and was used in 63.5% of administrations. MAEs for moments 2 and 3 were significantly reduced (p=0.0075) after implementation in the operating rooms and ICU.

conclusionAn updated BCMA technology contributes to a higher double check compliance and MAE reduction, especially when changing an empty syringe. BCMA technology has the potential to decrease MAEs if adherence is high enough.

Indexed as

Medication ErrorsOperating RoomsElectronic Data ProcessingHumansInfusion PumpsMedication Systems, HospitalAnaesthesiaHealthcare quality improvementMedication safetyPatient safetyQuality improvement

Identifiers

PMID37217240
PMCPMC10231014

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.