ArticleJournal of medical imaging (Bellingham, Wash.)2023
Fast 3D YOLOv3 based standard plane regression of vertebral bodies in intra-operative CBCT volumes.
Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Artificial intelligence and robotic technologies redefining precision and personalization in orthopedic surgery: a narrative review.Frontiers in bioengineering and biotechnology · 2026Review
- Artificial Intelligence in Orthopedic Surgery: Current Applications, Challenges, and Future Directions.MedComm · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Mobile C-arm systems represent the standard imaging devices within the field of spine surgery. In addition to 2D imaging, they allow for 3D scans while preserving unrestricted patient access. For viewing, the acquired volumes are adjusted such that their anatomical standard planes align with the axes of the viewing modality. This difficult and time-consuming step is currently performed manually by the leading surgeon. This process is automatized within this work to improve the usability of C-arm systems. Thereby, the spinal region consisting of multiple vertebrae and the standard planes of all vertebrae being of interest to the surgeon need to be taken into account. Approach: An object detection algorithm based on the you only look once version 3 architecture, adapted to 3D inputs, is compared with a segmentation-based approach employing a 3D U-Net. Both algorithms are trained on a dataset of 440 and tested on 218 spinal volumes. Results: Although the detection-based algorithm is slightly inferior concerning the detection (91% versus 97% accuracy), localization (1.26 mm versus 0.74 mm error) and alignment accuracy (5.00 deg versus 4.73 deg error), it outperforms the segmentation-based one in terms of speed (5 s versus 38 s). Conclusions: Both algorithms show similar good results. However, the speed gain of the detection-based algorithm, resulting in a run time of 5 s, makes it more suitable for usage in an intra-operative scenario.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.