Evidence map›Paper›PMID 37214151›Full record

ArticleJournal of pathology informatics2023

Validation of Remote Digital Pathology based diagnostic reporting of Frozen Sections from home.

Rajiv Kumar Kaushal, Subhash Yadav, Ayushi Sahay, Nupur Karnik, Tushar Agrawal, Vinayak Dave, Nikhil Singh, Ashish Shah, Sangeeta B Desai

Open access · goldAbstract read
In one paragraph

Article in Journal of pathology informatics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Rajiv Kumar KaushalDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Subhash YadavDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Ayushi SahayDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Nupur KarnikDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Tushar AgrawalDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Vinayak DaveDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Nikhil SinghDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Ashish ShahDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Sangeeta B DesaiDepartment of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India.
Tata Memorial Hospital · INHomi Bhabha National Institute · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Despite the promising applications of whole-slide imaging (WSI) for frozen section (FS) diagnosis, its adoption for remote reporting is limited. Objective: To assess the feasibility and performance of home-based remote digital consultation for FS diagnosis. Material & Method: Cases accessioned beyond regular working hours (5 pm-10 pm) were reported simultaneously using optical microscopy (OM) and WSI. Validation of WSI for FS diagnosis from a remote site, i.e. home, was performed by 5 pathologists. Cases were scanned using a portable scanner (Grundium Ocus®40) and previewed on consumer-grade computer devices through a web-based browser (http://grundium.net). Clinical data and diagnostic reports were shared through a google spreadsheet. The diagnostic concordance, inter- and intra-observer agreement for FS diagnosis by WSI versus OM, and turnaround time (TAT), were recorded. Results: The overall diagnostic accuracy for OM and WSI (from home) was 98.2% (range 97%-100%) and 97.6% (range 95%-99%), respectively, when compared with the reference standard. Almost perfect inter-observer (k = 0.993) and intra-observer (k = 0.987) agreement for WSI was observed by 4 pathologists. Pathologists used consumer-grade laptops/desktops with an average screen size of 14.58 inches (range = 12.3-17.7 inches) and a network speed of 64 megabits per second (range: 10-90 Mbps). The mean diagnostic assessment time per case for OM and WSI was 1:48 min and 5:54 min, respectively. Mean TAT of 27.27 min per case was observed using WSI from home. Seamless connectivity was observed in approximately 75% of cases. Conclusion: This study validates the role of WSI for remote FS diagnosis for its safe and efficient adoption in clinical use.

Indexed as

Digital pathologyFrozen sectionPrimary diagnosisRemote reportingValidationWhole-slide imaging

Identifiers

PMID37214151
PMCPMC10192998
OpenAlexW4365815729

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.