Evidence map›Paper›PMID 37213057›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

An autonomous X-ray image acquisition and interpretation system for assisting percutaneous pelvic fracture fixation.

Benjamin D Killeen, Cong Gao, Kanyifeechukwu J Oguine, Sean Darcy, Mehran Armand, Russell H Taylor, Greg Osgood, Mathias Unberath

Open access · greenAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. FluoroSAM: A Language-promptable Foundation Model for Flexible X-ray Image Segmentation.Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention · 2026
    Article
  3. Article
  4. Intelligent control of robotic X-ray devices using a language-promptable digital twin.International journal of computer assisted radiology and surgery · 2025
    Article
  5. Article
  6. Pelphix: Surgical Phase Recognition from X-ray Images in Percutaneous Pelvic Fixation.Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Benjamin D KilleenJohns Hopkins University, Baltimore, 21210, MD, USA. killeen@jhu.edu.ORCID http://orcid.org/0000-0003-2511-7929
Cong GaoJohns Hopkins University, Baltimore, 21210, MD, USA.
Kanyifeechukwu J OguineJohns Hopkins University, Baltimore, 21210, MD, USA.
Sean DarcyJohns Hopkins University, Baltimore, 21210, MD, USA.
Mehran ArmandJohns Hopkins University, Baltimore, 21210, MD, USA.
Russell H TaylorJohns Hopkins University, Baltimore, 21210, MD, USA.
Greg OsgoodDepartment of Orthopaedic Surgery, Johns Hopkins University, Baltimore, USA.
Mathias UnberathJohns Hopkins University, Baltimore, 21210, MD, USA.
Johns Hopkins University · US

Funding

Task-aware and Autonomous Robotic C-arm Servoing for Flouroscopy-guided InterventionsR21EB028505 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI UNBERATH, MATHIAS · 2020 to 2022
$629k
NIBIB NIH HHS R21 EB028505
6 · The paper itself

Abstract

purposePercutaneous fracture fixation involves multiple X-ray acquisitions to determine adequate tool trajectories in bony anatomy. In order to reduce time spent adjusting the X-ray imager's gantry, avoid excess acquisitions, and anticipate inadequate trajectories before penetrating bone, we propose an autonomous system for intra-operative feedback that combines robotic X-ray imaging and machine learning for automated image acquisition and interpretation, respectively.

methodsOur approach reconstructs an appropriate trajectory in a two-image sequence, where the optimal second viewpoint is determined based on analysis of the first image. A deep neural network is responsible for detecting the tool and corridor, here a K-wire and the superior pubic ramus, respectively, in these radiographs. The reconstructed corridor and K-wire pose are compared to determine likelihood of cortical breach, and both are visualized for the clinician in a mixed reality environment that is spatially registered to the patient and delivered by an optical see-through head-mounted display.

resultsWe assess the upper bounds on system performance through in silico evaluation across 11 CTs with fractures present, in which the corridor and K-wire are adequately reconstructed. In post hoc analysis of radiographs across 3 cadaveric specimens, our system determines the appropriate trajectory to within 2.8 ± 1.3 mm and 2.7 ± 1.8[Formula: see text].

conclusionAn expert user study with an anthropomorphic phantom demonstrates how our autonomous, integrated system requires fewer images and lower movement to guide and confirm adequate placement compared to current clinical practice. Code and data are available.

Indexed as

Fractures, BoneImaging, Three-DimensionalFluoroscopyFracture FixationFracture Fixation, InternalHumansTomography, X-Ray ComputedX-RaysAutonomous X-ray imagingC-arm positioningDeep learningMixed realityNeedle insertion

Identifiers

PMID37213057
PMCPMC11002911
OpenAlexW4377221373

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.