SynthesisBMC urology2023
A systematic review and meta-analysis of complications of artificial urinary sphincters in female patients with urinary incontinence due to internal sphincter insufficiency.
Synthesis in BMC urology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.
- Safety and outcome assessment of robot-assisted artificial urinary sphincter implantation in the treatment of urodynamic stress incontinence: a systematic review and single-arm meta-analysis.Journal of robotic surgery · 2025Pooled it
- Experimental evaluation of the optimum applied pressure and number of cuffs for artificial sphincter in fluid flow control in anAsian journal of urology · 2025Article
- Patients' Perceptions of Stress Urinary Incontinence Treatment: A Scoping Review of Qualitative Studies.International urogynecology journal · 2025Article
- Robotic-assisted artificial urinary sphincter implant complicated by ureteric obstruction.Central European journal of urology · 2025Article
- Neurobiological insights into lower urinary tract dysfunction: evaluating the role of brain-derived neurotrophic factor.American journal of clinical and experimental urology · 2023Review
- 5-Year results of robotic female AUS implantation: our single-center series of 42 patients.Therapeutic advances in urologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundUrinary incontinence (UI) is a common worldwide rising health issue among women with a prevalence of 5 to 70%. Stress urinary incontinence (SUI) is the most common subtype of UI. There are different treatments for UI, including AUS (artificial urinary sphincter) implantation, as one of the surgical options for treating SUI. The aim of this study was to determine the complication rate of AUS, exclusively in female patients with SUI, which resulted from ISD (intrinsic sphincter deficiency). We also compared the complication rate between minimally invasive (laparoscopic or robotic surgery) and open approaches.
methodsScopus, PubMed, Web of Science, Embase, and Google Scholar were searched for studies regarding complications in AUS implantation surgery, from the beginning of the project to March 2022. After screening and reviewing of full text, the general characteristics of the study and study population including follow-up time, type of surgery, and the number of complications that occurred such as necrosis, atrophy, erosion, infection, mechanical failure, revision, and leak, were extracted.
resultsWe found that atrophy occurred in 1 of 188 (0.53%) patients treated with minimally invasive surgery and in 1 of 669 (0.15%) patients treated with open surgery. None of the 17 included studies reported the occurrence of necrosis in the patients under study. Erosion occurred in 9 of 188 (4.78%) patients treated with minimally invasive surgery and in 41 of 669 (6.12%) patients treated with open surgery. Infection occurred in 12 of 188 (6.38%) patients treated with minimally invasive surgery and in 22 of 669 (3.2%) patients treated with open surgery. The mechanical failure occurred in 1 of 188 (0.53%) patients treated with minimally invasive surgery and in 55 of 669 (8.22%) patients treated with open surgery. Reconstructive surgery occurred in 7 of 188 (3.72%) patients treated with minimally invasive surgery and in 95 of 669 (14.2%) patients treated with open surgery. Leaks occurred in 4 of 188 (2.12%) patients treated with minimally invasive surgery and in 6 of 669 (0.89%) patients treated with open surgery. The type of surgery was associated with a statistically significant increase in mechanical failure (p-value = 0.067) and infection (p-value = 0.021), and reconstructive surgery (p-value = 0.049). Out of the 857 participats in the study,469 were studied for less than five years and 388 were studied for more than five years.21 of 469 (4.4%) (p-value = 0.08) patients and 81 of 388 (20.8%) (p-value = 0.001) patients required reconstructive surgery. Erosion occurred in 23 of 469 (4.9%) (p-value = 0.01)patients with following time less than five years and in 27 of 388 (6.9%) (p-value = 0.001) patients with following time more than five years.
conclusionThe use of artificial urinary sphincters in the treatment of UI causes complications such as atrophy, erosion, and infection; the amount of which is influenced by the surgical method and the duration of using the artificial urinary sphincter. It seems that the use of new surgical methods, such as laparoscopic surgery, is useful in reducing the incidence of complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.