Evidence map›Paper›PMID 37209355›Full record

ArticleJournal of robotic surgery2023

Improved accuracy of a novel fluoroscopy-based robotically assisted THA system compared to manual THA.

Graham B J Buchan, Christian J Hecht, David Liu, Lipalo Mokete, Daniel Kendoff, Atul F Kamath

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
6.4field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Graham B J BuchanDepartment of Orthopaedic Surgery, Cleveland Clinic Foundation, 9500 Euclid Ave, Cleveland, OH, 44195, USA.
Christian J HechtDepartment of Orthopaedic Surgery, Cleveland Clinic Foundation, 9500 Euclid Ave, Cleveland, OH, 44195, USA.
David LiuGold Coast Centre for Bone and Joint Surgery, 14 Sixth Ave, Palm Beach, QLD, 4421, Australia.
Lipalo MoketeConsultant Orthopaedic Surgeon, Charlotte Maxeke Johannesburg Academic Hospital, Busamed Modderfontein Hospital, Lecture University of the Witwatersand, 4 Cransley Crescent, Linbro Park, Sandton, Johannesburg, 2190, South Africa.
Daniel KendoffChefarzt Zentrum für Orthopädie und Unfallchirurgie, HELIOS Kliniken Berlin-Buch, Schwanebecker Chaussee 25, 13125, Berlin, Germany.
Atul F KamathDepartment of Orthopaedic Surgery, Cleveland Clinic Foundation, 9500 Euclid Ave, Cleveland, OH, 44195, USA. kamatha@ccf.org.
Cleveland Clinic · USJohannesburg Hospital · ZA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate acetabular cup position remains a persistent challenge in total hip arthroplasty (THA). Studies investigating the early outcomes of robotic-assisted THA (RA-THA) systems have shown improved cup placement compared to manual THA (mTHA) approaches, however, contemporary robotic platforms are reliant on pre-operative CT imaging. The goal of this study was to analyze the accuracy of a novel, fluoroscopy-based RA-THA system compared to an unassisted mTHA approach and determine the effect of the robotic system on operative time. We performed a retrospective cohort analysis on a consecutive series of 198 patients who received mTHA and RA-THA between March 2021 and July 2022. The primary outcome of interest was the accuracy of acetabular component placement, defined by average cup inclination and anteversion. Secondary outcomes included the proportion of acetabular cups positioned within the Lewinnek safe zone, operative time, and overall room time. The RA-THA group demonstrated significantly higher accuracy of acetabular anteversion to target compared to the manual group (18.5 vs. 21.7˚; p < 0.001), and had a significantly greater proportion of acetabular cups placed within the Lewinnek safe zone (81.6 vs. 59.0%; p < 0.001). The RA-THA cohort had longer operative times compared to mTHA group (39.0 vs. 35.3 min; p = 0.003), but no difference was seen in total operating room time (101.2 vs. 101.2 min; p = 0.982). This study demonstrates that the use of a novel, fluoroscopy-based, pin-less THA robotic platform increased the accuracy of acetabular cup placement, including a 22.6% improvement in safe zone placement, compared to mTHA approach, with no increase in overall case time.

Indexed as

Arthroplasty, Replacement, HipRobotic Surgical ProceduresFluoroscopyHumansRetrospective StudiesTreatment OutcomeAccuracyFluoroscopyHip replacementRobotic-assisted surgeryRobotic THATotal hip arthroplasty (THA)

Identifiers

PMID37209355
OpenAlexW4377140505

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.