Evidence map›Paper›PMID 37208553›Full record

ArticleMagma (New York, N.Y.)2023

In vivo quantitative MRI: T

Kalina V Jordanova, Michele N Martin, Stephen E Ogier, Megan E Poorman, Kathryn E Keenan

Open access · hybridAbstract read
In one paragraph

Article in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. MultidimensionalbioRxiv : the preprint server for biology · 2026
    Article
  3. Article
  4. Article
  5. Rapid quantitative MRI at 46 mT: Accelerated TMagnetic resonance in medicine · 2025
    Article
  6. Review
  7. Repeatability and reproducibility of rapid TImaging neuroscience (Cambridge, Mass.) · 2025
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Kalina V JordanovaPhysical Measurement Laboratory, National Institute of Standards and Technology, NIST, Boulder, CO, USA. kalina.jordanova@nist.gov.ORCID http://orcid.org/0000-0002-9097-3863
Michele N MartinPhysical Measurement Laboratory, National Institute of Standards and Technology, NIST, Boulder, CO, USA.
Stephen E OgierPhysical Measurement Laboratory, National Institute of Standards and Technology, NIST, Boulder, CO, USA.
Megan E PoormanHyperfine, Inc., Guilford, CT, USA.
Kathryn E KeenanPhysical Measurement Laboratory, National Institute of Standards and Technology, NIST, Boulder, CO, USA.
National Institute of Standards and Technology · US

Funding

Hyperfine, Inc. CRADANIST Professional Research Experience Program 70NANB18H006
6 · The paper itself

Abstract

objectiveTo measure healthy brain [Formula: see text] and [Formula: see text] relaxation times at 0.064 T. MATERIALS AND

methods[Formula: see text] and [Formula: see text] relaxation times were measured in vivo for 10 healthy volunteers using a 0.064 T magnetic resonance imaging (MRI) system and for 10 test samples on both the MRI and a separate 0.064 T nuclear magnetic resonance (NMR) system. In vivo [Formula: see text] and [Formula: see text] values are reported for white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF) for automatic segmentation regions and manual regions of interest (ROIs).

results[Formula: see text] sample measurements on the MRI system were within 10% of the NMR measurement for 9 samples, and one sample was within 11%. Eight [Formula: see text] sample MRI measurements were within 25% of the NMR measurement, and the two longest [Formula: see text] samples had more than 25% variation. Automatic segmentations generally resulted in larger [Formula: see text] and [Formula: see text] estimates than manual ROIs. DISCUSSION: [Formula: see text] and [Formula: see text] times for brain tissue were measured at 0.064 T. Test samples demonstrated accuracy in WM and GM ranges of values but underestimated long [Formula: see text] in the CSF range. This work contributes to measuring quantitative MRI properties of the human body at a range of field strengths.

Indexed as

Magnetic Resonance ImagingWhite MatterBrainGray MatterHumansMagnetic Resonance SpectroscopyMagnetic resonance imaging

Identifiers

PMID37208553
PMCPMC10386946
OpenAlexW4377086684

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.