Evidence map›Paper›PMID 37208302›Full record

Trial reportEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2023

Effects of hyperbaric exposure on mechanical and electronic parameters of implantable cardioverter-defibrillators.

Romain Guenneugues, Anne Henckes, Vincent Mansourati, Jacques Mansourati

Open access · hybridAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Transvenous cardiac implantable electronic devices withstand contact sports in an experimental model.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  3. Hyperbaric Oxygen Therapy for the Treatment of Bone-Related Diseases.International journal of molecular sciences · 2025
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Romain GuenneuguesHyperbaric Medicine Unit, University Hospital of Brest, Bvd Tanguy Prigent, 29609 Brest Cedex, France.
Anne HenckesHyperbaric Medicine Unit, University Hospital of Brest, Bvd Tanguy Prigent, 29609 Brest Cedex, France.ORCID 0000-0002-5662-5216
Vincent MansouratiDepartment of Cardiology, University Hospital of Brest, Bvd Tanguy Prigent, 29609 Brest Cedex, France.ORCID 0009-0008-1654-6717
Jacques MansouratiDepartment of Cardiology, University Hospital of Brest, Bvd Tanguy Prigent, 29609 Brest Cedex, France.ORCID 0000-0002-6697-7194
Centre Hospitalier Régional Universitaire de Brest · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsHyperbaric oxygen therapy (HBOT) is the standard adjuvant treatment for life-threatening or disabling pathologies. Currently, mechanical and electronic variations of implantable cardioverter-defibrillators (ICD) in hyperbaric conditions have not been evaluated. As a result, many patients eligible for HBOT but ICD recipients cannot undergo this therapy, even in emergency situations. METHODS AND

resultsTwenty-two explanted ICD of various brands and models were randomized in two groups: single hyperbaric exposure at an absolute pressure of 4000 hPa and 30 iterative hyperbaric exposures at an absolute pressure of 4000 hPa. Mechanical and electronic parameters of these ICD were blindly assessed before, during, and after hyperbaric exposures. Regardless of the hyperbaric exposure, we could not find any mechanical distortion, inappropriate occurrence of anti-tachycardia therapies, dysfunction of tachyarrhythmia therapeutic programming, or dysfunction of programmed pacing parameters.

conclusionDry hyperbaric exposure seems harmless on ICD tested ex vivo. This result may lead to a reconsideration of the absolute contraindication of emergency HBOT to ICD recipients. A real-life study in these patients with an indication to HBOT should be performed to assess their tolerance to the treatment.

Indexed as

Defibrillators, ImplantableTachycardia, VentricularHumansHyperbaric exposureHyperbaric oxygen therapyICD

Identifiers

PMID37208302
PMCPMC10198771
OpenAlexW4377115821

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.