Evidence map›Paper›PMID 37207039›Full record

ArticleJournal of chemical health & safety2022

Feasibility of a Selective Epoxidation Technique for Use in Quantification of Peracetic Acid in Air Samples Collected on Sorbent Tubes.

Callee M Walsh, Stephen R Jackson, Notashia N Baughman, Jason E Ham, J R Wells

Abstract read
In one paragraph

Article in Journal of chemical health & safety, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Callee M WalshExposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, United States.ORCID 0000-0002-3368-9209
Stephen R JacksonExposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, United States; Present Address: Office of Research and Development, United States Environmental Protection Agency, Research Triangle Park, North Carolina 27711, United States.
Notashia N BaughmanExposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, United States.
Jason E HamExposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, United States.ORCID 0000-0001-7707-1550
J R WellsExposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, United States.ORCID 0000-0002-3472-0028

Funding

Intramural CDC HHS CC999999
6 · The paper itself

Abstract

Peracetic acid is a disinfection agent used in medical and food processing facilities, and occupational exposures have been documented. To facilitate characterization of daily occupational exposures, the current work describes the development of a personal sampling technique to quantify the peracetic acid concentration in air samples. Peracetic acid atmospheres were generated in 100 L Teflon chambers, and samples were collected on 350 mg XAD-7 solid sorbent tubes for 4 h at a flow rate of 250 mL/min using a personal sampling pump. Indirect measurement of peracetic acid was achieved by desorption from the sorbent and subsequent treatment with cyclohexene to initiate an epoxidation reaction, formally known as the Prilezhaev reaction. The epoxidation product, cyclohexene oxide, was quantified by gas chromatography-mass spectrometry. The reaction enabled quantification of peracetic acid with high specificity over the common co-contaminants hydrogen peroxide and acetic acid, which were introduced in 10-fold and 100-fold excess to challenge the reaction. The technique also demonstrated an overall estimate of bias and precision of 11 and 8%, respectively, and a limit of detection of 60 ppbv was estimated. Preliminary storage experiments indicate that unreacted peracetic acid is stable on the sorbent tubes for 72 h when stored at -20 °C following collection. Overall, the specificity of the reaction and capability to sample for longer time periods than current methods, in addition to the use of safer personal sampling materials, demonstrate the utility of this technique for peracetic acid measurement in air.

Indexed as

disinfectionoccupational exposure surveillanceperoxyacetic acidsorbent

Identifiers

PMID37207039
PMCPMC10191181

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.