Evidence map›Paper›PMID 37206226›Full record

ArticleBioengineering & translational medicine2023

Automated assessment of human engineered heart tissues using deep learning and template matching for segmentation and tracking.

José M Rivera-Arbeláez, Danjel Keekstra, Carla Cofiño-Fabres, Tom Boonen, Milica Dostanic, Simone A Ten Den, Kim Vermeul, Massimo Mastrangeli, Albert van den Berg, Loes I Segerink and 3 more

Abstract read
In one paragraph

Article in Bioengineering & translational medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

José M Rivera-ArbeláezDepartment of Applied Stem Cell Technologies, TechMed Centre University of Twente Enschede the Netherlands.ORCID https://orcid.org/0000-0002-0075-6006
Danjel KeekstraData Management & Biometrics (DMB) Group University of Twente Enschede the Netherlands.
Carla Cofiño-FabresDepartment of Applied Stem Cell Technologies, TechMed Centre University of Twente Enschede the Netherlands.
Tom BoonenRiver BioMedics Enschede the Netherlands.
Milica DostanicMicroelectronics, TU Delft Delft the Netherlands.
Simone A Ten DenDepartment of Applied Stem Cell Technologies, TechMed Centre University of Twente Enschede the Netherlands.
Kim VermeulDepartment of Applied Stem Cell Technologies, TechMed Centre University of Twente Enschede the Netherlands.
Massimo MastrangeliMicroelectronics, TU Delft Delft the Netherlands.
Albert van den BergBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, TechMed Centre, Max Planck Institute for Complex Fluid Dynamics University of Twente Enschede the Netherlands.
Loes I SegerinkBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, TechMed Centre, Max Planck Institute for Complex Fluid Dynamics University of Twente Enschede the Netherlands.
Marcelo C RibeiroRiver BioMedics Enschede the Netherlands.
Nicola StrisciuglioData Management & Biometrics (DMB) Group University of Twente Enschede the Netherlands.
Robert PassierDepartment of Applied Stem Cell Technologies, TechMed Centre University of Twente Enschede the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The high rate of drug withdrawal from the market due to cardiovascular toxicity or lack of efficacy, the economic burden, and extremely long time before a compound reaches the market, have increased the relevance of human in vitro models like human (patient-derived) pluripotent stem cell (hPSC)-derived engineered heart tissues (EHTs) for the evaluation of the efficacy and toxicity of compounds at the early phase in the drug development pipeline. Consequently, the EHT contractile properties are highly relevant parameters for the analysis of cardiotoxicity, disease phenotype, and longitudinal measurements of cardiac function over time. In this study, we developed and validated the software HAARTA (Highly Accurate, Automatic and Robust Tracking Algorithm), which automatically analyzes contractile properties of EHTs by segmenting and tracking brightfield videos, using deep learning and template matching with sub-pixel precision. We demonstrate the robustness, accuracy, and computational efficiency of the software by comparing it to the state-of-the-art method (MUSCLEMOTION), and by testing it with a data set of EHTs from three different hPSC lines. HAARTA will facilitate standardized analysis of contractile properties of EHTs, which will be beneficial for in vitro drug screening and longitudinal measurements of cardiac function.

Indexed as

automated trackingcardiac performancecontractile forcedeep learningengineered heart tissuessegmentationsub‐pixel interpolationtemplate matching

Identifiers

PMID37206226
PMCPMC10189437

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.