Evidence map›Paper›PMID 37206133›Full record

ArticleBiomedical optics express2023

Non-uniform image reconstruction for fast photoacoustic microscopy of histology imaging.

Ling Xiao Zhou, Yu Xia, Renxiang Dai, An Ran Liu, Si Wei Zhu, Peng Shi, Wei Song, Xiao Cong Yuan

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Ling Xiao ZhouNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.
Yu XiaNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.
Renxiang DaiNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.
An Ran LiuNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.
Si Wei ZhuThe Institute of Translational Medicine, Tianjin Union Medical Center of Nankai University, Tianjin, 300121, China.
Peng ShiNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.ORCID https://orcid.org/0000-0001-9583-9412
Wei SongNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.
Xiao Cong YuanNanophotonics Research Center, Shenchen Key Laboratory of Micro-Scale Optica Formation Technology, Institute of Microscale Optoelectronics Shenchen University, Shenchen, 518060, China.
Nankai University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photoacoustic microscopic imaging utilizes the characteristic optical absorption properties of pigmented materials in tissues to enable label-free observation of fine morphological and structural features. Since DNA/RNA can strongly absorb ultraviolet light, ultraviolet photoacoustic microscopy can highlight the cell nucleus without complicated sample preparations such as staining, which is comparable to the standard pathological images. Further improvements in the imaging acquisition speed are critical to advancing the clinical translation of photoacoustic histology imaging technology. However, improving the imaging speed with additional hardware is hampered by considerable costs and complex design. In this work, considering heavy redundancy in the biological photoacoustic images that overconsume the computing power, we propose an image reconstruction framework called non-uniform image reconstruction (NFSR), which exploits an object detection network to reconstruct low-sampled photoacoustic histology images into high-resolution images. The sampling speed of photoacoustic histology imaging is significantly improved, saving 90% of the time cost. Furthermore, NFSR focuses on the reconstruction of the region of interest while maintaining high PSNR and SSIM evaluation indicators of more than 99% but reducing the overall computation by 60%.

Identifiers

PMID37206133
PMCPMC10191656
OpenAlexW4362641075

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.