Evidence map›Paper›PMID 37203314›Full record

ArticleMagnetic resonance in medicine2023

Live-view 4D GRASP MRI: A framework for robust real-time respiratory motion tracking with a sub-second imaging latency.

Li Feng

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. MRI of GlycoNOE in the human liver using GraspNOE-Dixon.Magnetic resonance in medicine · 2025
    Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Li FengCenter for Advanced Imaging Innovation and Research (CAI2R), New York University Grossman School of Medicine, New York, New York, USA.ORCID 0000-0002-8692-7645

Funding

TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Christopher M Collins · 2014 to 2026
$19.3M
Rapid Motion-Robust and Easy-to-Use Dynamic Contrast-Enhanced MRI for Liver Perfusion QuantificationR01EB030549 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI FENG, LI · 2021 to 2024
$1.7M
Rapid Structure-Function MRI of the Lung for Post-COVID-19 ManagementR01EB031083 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI FENG, LI · 2021 to 2021
$1.5M
3D Free-Breathing Fat and Iron Corrected T1 MappingR21EB032917 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI FENG, LI · 2022 to 2023
$465k
NIBIB NIH HHS P41 EB017183NIBIB NIH HHS R01 EB030549NIBIB NIH HHS R01 EB031083NIBIB NIH HHS R21 EB032917
6 · The paper itself

Abstract

purposeTo propose a framework called live-view golden-angle radial sparse parallel (GRASP) MRI for low-latency and high-fidelity real-time volumetric MRI.

methodsLive-view GRASP MRI has two stages. The first one is called an off-view stage and the second one is called a live-view stage. In the off-view stage, 3D k-space data and 2D navigators are acquired alternatively using a new navi-stack-of-stars sampling scheme. A 4D motion database is then generated that contains time-resolved MR images at a sub-second temporal resolution, and each image is linked to a 2D navigator. In the live-view stage, only 2D navigators are acquired. At each time point, a live-view 2D navigator is matched to all the off-view 2D navigators. A 3D image that is linked to the best-matched off-view 2D navigator is then selected for this time point. This framework places the typical acquisition and reconstruction burden of MRI in the off-view stage, enabling low-latency real-time 3D imaging in the live-view stage. The accuracy of live-view GRASP MRI and the robustness of 2D navigators for characterizing respiratory variations and/or body movements were assessed.

resultsLive-view GRASP MRI can efficiently generate real-time volumetric images that match well with the ground-truth references, with an imaging latency below 500 ms. Compared to 1D navigators, 2D navigators enable more reliable characterization of respiratory variations and/or body movements that may occur throughout the two imaging stages.

conclusionLive-view GRASP MRI represents a novel, accurate, and robust framework for real-time volumetric imaging, which can potentially be applied for motion adaptive radiotherapy on MRI-Linac.

Indexed as

Magnetic Resonance ImagingRespirationImaging, Three-DimensionalMotionMovementGRASPlive-viewMRI-Linacnavi-stack-of-starsreal-time imagingrespiratory motion

Identifiers

PMID37203314
PMCPMC10330383

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.