ArticleBMC musculoskeletal disorders2023
How is hip anatomy reconstruction and inlay wear associated up to 10 years after primary THA using ceramic on highly crosslinked polyethylene bearings?
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Hybrid Automatic Model for Circle Detection in X-Ray Imagery: A Case Study on Hip Prosthesis Wear.Bioengineering (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionConventional polyethylene (PE) wear has been reported to be associated with femoral offset reconstruction and cup orientation after THA. Thus, the present study aimed (1) to determine the polyethylene wear rate of 32 mm ceramic heads with highly cross-linked polyethylene (HXLPE) inlays up to 10 years postoperatively and (2) to identify patient and surgery-related factors affecting the wear rate.
methodsA prospective cohort study was performed, investigating 101 patients with 101 cementless THAs and ceramic (32 mm) on HXLPE bearings after 6-24 months, 2-5 years and 5-10 years postoperatively. The linear wear rate was determined using a validated software (PolyWare®, Rev 8, Draftware Inc, North Webster, IN, USA) by two reviewers, blinded to each other. A linear regression model was used to identify patient and surgery-related factors on HXLPE -wear.
resultsAfter an initial bedding-in phase of 1 year after surgery, the mean linear wear rate was 0.059 ± 0.031 mm/y at ten years (mean 7.7 years; SD 0.6 years, range 6-10), being below the osteolysis relevant threshold of 0.1 mm/year. The regression analysis demonstrated that age at surgery, BMI, cup inclination or anteversion and the UCLA score were not associated with the linear HXLPE-wear rate. Only increased femoral offset showed a significant correlation with an increased HXLPE-wear rate (correlation coefficient of 0.303; p = 0.003) with a moderate clinical effect size (Cohen's f²=0.11).
conclusionIn contrast to conventional PE inlays, hip arthroplasty surgeons may be less concerned about osteolysis-related wear of the HXLPE if the femoral offset is slightly increased. This allows focusing on joint anatomy reconstruction, hip stability and leg length.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.