Evidence map›Paper›PMID 37202656›Full record

ReviewMagma (New York, N.Y.)2023

Tackling SNR at low-field: a review of hardware approaches for point-of-care systems.

Andrew Webb, Thomas O'Reilly

Open access · hybridAbstract readReview
In one paragraph

Review in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
5.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Circuit design for broadband decoupling in multi-coil multi-nuclear applications.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Coupled stack-up volume RF coils for low-field open MR imaging.medRxiv : the preprint server for health sciences · 2024
    Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Andrew WebbDepartment of Radiology, C.J. Gorter MRI Center, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands. a.webb@lumc.nl.ORCID http://orcid.org/0000-0003-4045-9732
Thomas O'ReillyDepartment of Radiology, C.J. Gorter MRI Center, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands.
Leiden University Medical Center · NL

Funding

Horizon 2020 Framework Programme 670629
6 · The paper itself

Abstract

objectiveTo review the major hardware components of low-field point-of-care MRI systems which affect the overall sensitivity.

methodsDesigns for the following components are reviewed and analyzed: magnet, RF coils, transmit/receive switches, preamplifiers, data acquisition system, and methods for grounding and mitigating electromagnetic interference.

resultsHigh homogeneity magnets can be produced in a variety of different designs including C- and H-shaped as well as Halbach arrays. Using Litz wire for RF coil designs enables unloaded Q values of ~ 400 to be reached, with body loss representing about 35% of the total system resistance. There are a number of different schemes to tackle issues arising from the low coil bandwidth with respect to the imaging bandwidth. Finally, the effects of good RF shielding, proper electrical grounding, and effective electromagnetic interference reduction can lead to substantial increases in image signal-to-noise ratio. DISCUSSION: There are many different magnet and RF coil designs in the literature, and to enable meaningful comparisons and optimizations to be performed it would be very helpful to determine a standardized set of sensitivity measures, irrespective of design.

Indexed as

Magnetic Resonance ImagingPoint-of-Care SystemsEquipment DesignPhantoms, ImagingRadio WavesSignal-To-Noise RatioGroundingLitz wireLow-field MRIMagnetsPoint-of-careRF coilsShielding

Identifiers

PMID37202656
PMCPMC10386948
OpenAlexW4377046924

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.