Evidence map›Paper›PMID 37202654›Full record

ArticleMagma (New York, N.Y.)2023

Impact of compressed sensing (CS) acceleration of two-dimensional (2D) flow sequences in clinical paediatric cardiovascular magnetic resonance (CMR).

Sara Moscatelli, Peter Gatehouse, Sylvia Krupickova, Raad Mohiaddin, Inga Voges, Daniel Giese, Sonia Nielles-Vallespin, Dudley J Pennell

Abstract read
In one paragraph

Article in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sara MoscatelliDepartment of Paediatric Cardiology, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK.
Peter GatehouseDepartment of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK. p.gatehouse@rbht.nhs.uk.ORCID http://orcid.org/0000-0002-0260-4719
Sylvia KrupickovaDepartment of Paediatric Cardiology, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK.
Raad MohiaddinDepartment of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK.
Inga VogesDepartment of Congenital Heart Disease and Pediatric Cardiology, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany.
Daniel GieseMagnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany.
Sonia Nielles-VallespinDepartment of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK.
Dudley J PennellDepartment of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK.

Funding

British Heart Foundation RG/19/1/34160
6 · The paper itself

Abstract

objectivesTwo-dimensional (2D) through-plane phase-contrast (PC) cine flow imaging assesses shunts and valve regurgitations in paediatric CMR and is considered the reference standard for Clinical quantification of blood Flow (COF). However, longer breath-holds (BH) can reduce compliance with possibly large respiratory manoeuvres altering flow. We hypothesize that reduced BH time by application of CS (Short BH quantification of Flow) (SBOF) retains accuracy while enabling faster, potentially more reliable flows. We investigate the variance between COF and SBOF cine flows.

methodsMain pulmonary artery (MPA) and sinotubular junction (STJ) planes were acquired at 1.5 T in paediatric patients by COF and SBOF.

results21 patients (mean age 13.9, 10-17y) were enrolled. The BH times were COF mean 11.7 s (range 8.4-20.9 s) vs SBOF mean 6.5 s (min 3.6-9.1 s). The differences and 95% CI between the COF and SBOF flows were LVSV -1.43 ± 13.6(ml/beat), LVCO 0.16 ± 1.35(l/min) and RVSV 2.95 ± 12.3(ml/beat), RVCO 0.27 ± 0.96(l/min), QP/QS were SV 0.04 ± 0.19, CO 0.02 ± 0.23. Variability between COF and SBOF did not exceed intrasession variation of COF.

conclusionSBOF reduces breath-hold duration to 56% of COF. RV flow by SBOF was biased compared to COF. The variation (95% CI) between COF and SBOF was similar to the COF intrasession test-retest 95% CI.

Indexed as

Magnetic Resonance ImagingMagnetic Resonance Imaging, CineBreath HoldingChildHumansLungMagnetic Resonance SpectroscopyReproducibility of ResultsArteriesBlood FlowMagnetic Resonance ImagingPediatrics

Identifiers

PMID37202654
PMCPMC10667407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.