Evidence map›Paper›PMID 37198194›Full record

ArticleScientific reports2023

A Doppler-exclusive non-invasive computational diagnostic framework for personalized transcatheter aortic valve replacement.

Nikrouz Bahadormanesh, Benjamin Tomka, Mohamed Abdelkhalek, Seyedvahid Khodaei, Nima Maftoon, Zahra Keshavarz-Motamed

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Nikrouz BahadormaneshDepartment of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada.
Benjamin TomkaDepartment of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada.
Mohamed AbdelkhalekSchool of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
Seyedvahid KhodaeiDepartment of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada.
Nima MaftoonDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada.
Zahra Keshavarz-MotamedDepartment of Mechanical Engineering, McMaster University, JHE-310, Hamilton, ON, L8S 4L7, Canada. motamedz@mcmaster.ca.
McMaster University · CAUniversity of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Given the associated risks with transcatheter aortic valve replacement (TAVR), it is crucial to determine how the implant will affect the valve dynamics and cardiac function, and if TAVR will improve or worsen the outcome of the patient. Effective treatment strategies, indeed, rely heavily on the complete understanding of the valve dynamics. We developed an innovative Doppler-exclusive non-invasive computational framework that can function as a diagnostic tool to assess valve dynamics in patients with aortic stenosis in both pre- and post-TAVR status. Clinical Doppler pressure was reduced by TAVR (52.2 ± 20.4 vs. 17.3 ± 13.8 [mmHg], p < 0.001), but it was not always accompanied by improvements in valve dynamics and left ventricle (LV) hemodynamics metrics. TAVR had no effect on LV workload in 4 patients, and LV workload post-TAVR significantly rose in 4 other patients. Despite the group level improvements in maximum LV pressure (166.4 ± 32.2 vs 131.4 ± 16.9 [mmHg], p < 0.05), only 5 of the 12 patients (41%) had a decrease in LV pressure. Moreover, TAVR did not always improve valve dynamics. TAVR did not necessarily result in a decrease (in 9 out of 12 patients investigated in this study) in major principal stress on the aortic valve leaflets which is one of the main contributors in valve degeneration and, consequently, failure of heart valves. Diastolic stresses increased significantly post-TAVR (34%, 109% and 81%, p < 0.001) for each left, right and non-coronary leaflets respectively. Moreover, we quantified the stiffness and material properties of aortic valve leaflets which correspond with the reduced calcified region average stiffness among leaflets (66%, 74% and 62%; p < 0.001; N = 12). Valve dynamics post-intervention should be quantified and monitored to ensure the improvement of patient conditions and prevent any further complications. Improper evaluation of biomechanical valve features pre-intervention as well as post-intervention may result in harmful effects post-TAVR in patients including paravalvular leaks, valve degeneration, failure of TAVR and heart failure.

Indexed as

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementAortic ValveHemodynamicsHumansTreatment Outcome

Identifiers

PMID37198194
PMCPMC10192526
OpenAlexW4376958718

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.