Evidence map›Paper›PMID 37197284›Full record

ArticleNMC case report journal2023

Enterprise Treatment for Recurrent Basilar Tip Aneurysm after PulseRider-assisted Coil Embolization: A Case Report.

Takahiro Yokoyama, Tatsuya Ishikawa, Yosuke Moteki, Takayuki Funatsu, Koji Yamaguchi, Seiichiro Eguchi, Hayato Yamahata, Buntou Ro, Takakazu Kawamata

Open access · diamondAbstract readCase Reports
In one paragraph

Article in NMC case report journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 87% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Takahiro YokoyamaDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Tatsuya IshikawaDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Yosuke MotekiDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Takayuki FunatsuDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Koji YamaguchiDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Seiichiro EguchiDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Hayato YamahataDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Buntou RoDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Takakazu KawamataDepartment of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan.
Tokyo Women's Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PulseRider (Cerenovus, Irvine, CA, USA) is a relatively novel device used for the treatment of wide-neck aneurysms with a coil-assisted effect. However, treatment options for recurrent aneurysms after PulseRider-assisted coil embolization remain controversial. Here we report a case of recurrent basilar tip aneurysm (BTA) treated with Enterprise 2 after PulseRider-assisted coil embolization. A woman in her 70s underwent coil embolization for a subarachnoid hemorrhage with ruptured BTA 16 years ago. Recurrence was detected at 6-year follow-up, and an additional coil embolization was performed. Nevertheless, gradual recurrence still occurred, and PulseRider-assisted coil embolization was performed without any complications 9 years after the second treatment. However, recurrence was detected once more at 6-month follow-up. Thus, stent-assisted coil embolization using Enterprise 2 (Cerenovus) through PulseRider was selected for angular remodeling. Enterprise 2 was deployed between the right P2 segment of the posterior cerebral artery (PCA) and basilar artery (BA) after an effective coil embolization, which achieved effective angular remodeling between the right PCA and BA. The patient's postoperative course was uneventful, and no recanalization was detected after half a year. Although PulseRider is effective for wide-neck aneurysm treatment, recurrence remains a possibility. Additional treatment using Enterprise 2 is safe and effective with the expectation of angular remodeling.

Indexed as

angular remodelingbasilar tip aneurysmclosed-cell stentEnterprisePulseRider

Identifiers

PMID37197284
PMCPMC10185358
OpenAlexW4366550454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.