Evidence map›Paper›PMID 37197035›Full record

ArticleOrthopaedic journal of sports medicine2023

Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS.

RobRoy L Martin, Joshua D Harris, Thomas Ellis, Robert Kollmorgen

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

RobRoy L MartinDepartment of Physical Therapy, Rangos School of Health Sciences, Duquesne University, Pittsburgh, Pennsylvania, USA.
Joshua D HarrisDepartment of Orthopaedic Surgery, Houston Methodist, Houston, Texas, USA.ORCID https://orcid.org/0000-0002-7606-2473
Thomas EllisOrthopedic One, Dublin, Ohio, USA.
Robert KollmorgenDepartment of Orthopedic Surgery, UCSF Fresno, Fresno, California, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) has not been fully evaluated for outcomes assessment after hip arthroscopy to correct femoroacetabular impingement syndrome (FAIS). Purpose/Hypothesis: The purpose of this study was to compare the accuracy of the PROMIS Physical Function (PF) and Pain Interference (PI) subscales with the 12-Item International Hip Outcome Tool (iHOT-12) to define patients with 3 unique substantial clinical benefit (SCB) scores-patients who reported ≥80%, ≥90%, and 100% satisfaction at 1 year after hip arthroscopy for FAIS. We hypothesized that the iHOT-12 would be more accurate than the PROMIS-PF and PROMIS-PI subscales in identifying these 3 patient groups. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: We reviewed the records of patients who underwent hip arthroscopy for symptomatic FAIS at 3 centers from January 2019 through June 2021 and had 1-year clinical and radiographic follow-up data. Patients completed the iHOT-12, PROMIS-PF, and PROMIS-PI on initial assessment and at 1 year (±30 days) postoperatively. Postoperative satisfaction was reported on an 11-category scale with anchors defined as "0% satisfied" and "100% satisfied." Receiver operator characteristic analysis was performed to determine the absolute SCB values for the iHOT-12 and PROMIS subscales that would most accurately identify those patients who reported ≥80%, ≥90%, and 100% satisfaction. Area under the curve (AUC) values and 95% CIs for the 3 instruments were compared. Results: Included were 163 patients (111 [68%] women and 52 [32%] men), with a mean age of 26.1 years. Corresponding absolute SCB scores for patients who reported ≥80%, ≥90%, and 100% satisfaction were as follows: iHOT-12, 68.4, 72.1, 74.7; PROMIS-PF, 45, 47.7, 49.9; and PROMIS-PI, 55.9, 52.4, 51.9. The AUC ranged between 0.67 and 0.82, with overlapping 95% CIs indicating a minimal difference in accuracy between the 3 instruments. Sensitivity and specificity values ranged between 0.61 and 0.82. Conclusion: The PROMIS-PF and PROMIS-PI subscales were as accurate as the iHOT-12 in defining absolute SCB scores for patients reporting ≥80%, ≥90%, and 100% satisfaction at 1-year follow-up after hip arthroscopy for FAIS.

Indexed as

arthroscopic surgeryhip jointoutcome measure

Identifiers

PMID37197035
PMCPMC10184234

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.