Evidence map›Paper›PMID 37195317›Full record

ArticleRadiation and environmental biophysics2023

Improving radiation dosimetry with an automated micronucleus scoring system: correction of automated scoring errors.

Younghyun Lee, Young Woo Jin, Ki Moon Seong, Ruth C Wilkins, Seongjae Jang

Open access · hybridAbstract read
In one paragraph

Article in Radiation and environmental biophysics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Younghyun LeeLaboratory of Biological Dosimetry, Korea Institute of Radiological and Medical Sciences, National Radiation Emergency Medical Center, Seoul, Republic of Korea.
Young Woo JinKorea Institute of Radiological and Medical Sciences, National Radiation Emergency Medical Center, Seoul, Republic of Korea.
Ki Moon SeongLaboratory of Biological Dosimetry, Korea Institute of Radiological and Medical Sciences, National Radiation Emergency Medical Center, Seoul, Republic of Korea.
Ruth C WilkinsConsumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, ON, Canada.
Seongjae JangLaboratory of Biological Dosimetry, Korea Institute of Radiological and Medical Sciences, National Radiation Emergency Medical Center, Seoul, Republic of Korea. sjsjj@kirams.re.kr.
Korea Institute of Radiological and Medical Sciences · KRHealth Canada · CASoonchunhyang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Radiation dose estimations performed by automated counting of micronuclei (MN) have been studied for their utility for triage following large-scale radiological incidents; although speed is essential, it also is essential to estimate radiation doses as accurately as possible for long-term epidemiological follow-up. Our goal in this study was to evaluate and improve the performance of automated MN counting for biodosimetry using the cytokinesis-block micronucleus (CBMN) assay. We measured false detection rates and used them to improve the accuracy of dosimetry. The average false-positive rate for binucleated cells was 1.14%; average false-positive and -negative MN rates were 1.03% and 3.50%, respectively. Detection errors seemed to be correlated with radiation dose. Correction of errors by visual inspection of images used for automated counting, called the semi-automated and manual scoring method, increased accuracy of dose estimation. Our findings suggest that dose assessment of the automated MN scoring system can be improved by subsequent error correction, which could be useful for performing biodosimetry on large numbers of people rapidly, accurately, and efficiently.

Indexed as

Cell NucleusRadiometryCytokinesisDose-Response Relationship, RadiationHumansLymphocytesMicronucleus TestsAutomated scoringBiodosimetryMicronuclei assayRadiation exposure

Identifiers

PMID37195317
PMCPMC10356889
OpenAlexW4376871180

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.